100% Latest & Updated Cisco 400-007 Practice Test Questions, Exam Dumps & Verified Answers!
30 Days Free Updates, Instant Download!
Question 370
A recently acquired region uses a routing protocol that cannot interoperate at the required boundary without redistribution. Which THREE statements are directly supported by the scenario and its technical evidence?
- Simulate route feedback and failover across the redistribution boundary using representative prefixes.
- Define an explicit redistribution boundary with loop prevention and a longer-term consolidation design.
- The familiar design meets recovery time with manageable on-call support.
- Run operational fault drills and compare measured convergence against the service SLA.
- Prefer the existing protocol with tested scale and failure performance, documenting a real trigger before changing it.
- No loops or unintended transit routes appear during migration.
Explanation
Correct Answers
A:Supported design and verification element: This check exercises the critical trade-off because Protocol coexistence sometimes demands a controlled interoperability mechanism before consolidation. Its specific acceptance evidence is: No loops or unintended transit routes appear during migration. Design task 3.1.b requires evidence of actual behavior rather than only configuration presence. [Family R165-F037, scenario R165-C074, item R165-Q0370.]
B:Supported design and verification element: This decision addresses the governing constraint because Protocol coexistence sometimes demands a controlled interoperability mechanism before consolidation. Verify using: Simulate route feedback and failover across the redistribution boundary using representative prefixes. The intended result is: No loops or unintended transit routes appear during migration. It maps to Cisco CCDE v3.1 task 3.1.b. [Family R165-F037, scenario R165-C074, item R165-Q0370.]
F:Supported design and verification element: This validates the outcome that matters: Protocol coexistence sometimes demands a controlled interoperability mechanism before consolidation. The agreed action is Define an explicit redistribution boundary with loop prevention and a longer-term consolidation design. and the confirming method is Simulate route feedback and failover across the redistribution boundary using representative prefixes. (Cisco task 3.1.b). [Family R165-F037, scenario R165-C074, item R165-Q0370.]
Incorrect Answers
C:This result would establish success for Operations skill alignment for routing protocol — constraint A, not the stated requirement. Here, Protocol coexistence sometimes demands a controlled interoperability mechanism before consolidation. The measurable acceptance condition is No loops or unintended transit routes appear during migration. [Family R165-F037, scenario R165-C074, item R165-Q0370.]
D:This check is valid for a different setting, Operations skill alignment for routing protocol — constraint A, because Manageability and proven recovery can matter more than a speculative benchmark advantage. In this scenario the discriminating evidence is Simulate route feedback and failover across the redistribution boundary using representative prefixes. because Protocol coexistence sometimes demands a controlled interoperability mechanism before consolidation. [Family R165-F037, scenario R165-C074, item R165-Q0370.]
E:This proposal matches the different constraint in Operations skill alignment for routing protocol — constraint A, where Manageability and proven recovery can matter more than a speculative benchmark advantage. Here, Protocol coexistence sometimes demands a controlled interoperability mechanism before consolidation. The relevant response is Define an explicit redistribution boundary with loop prevention and a longer-term consolidation design. [Family R165-F037, scenario R165-C074, item R165-Q0370.]
Question 371
NOC probes for manufacturing devices originate from a blocked management subnet and repeatedly trigger false outage alarms. Which design decision BEST satisfies the stated hard constraints without substituting unrelated capacity?
- Keep a version-controlled local configuration repository with a simple documented commit process.
- Add directional synthetic probes and path telemetry rather than relying on ICMP router liveness.
- Design dual-stack security, route reachability and DNS records as coordinated IPv4-and-IPv6 requirements.
- Design dedicated permitted monitoring paths and authenticated observability consistent with segmentation.
Explanation
Correct Answer
D:This decision addresses the governing constraint because Monitoring design must respect security zones and avoid interpreting intentional denial as failure. Verify using: Compare service health from authorized zone collectors and blocked NOC probes. The intended result is: Alerting reflects actual service availability without creating unrestricted management access. It maps to Cisco CCDE v3.1 task 3.1.b. [Family R165-F038, scenario R165-C075, item R165-Q0371.]
Incorrect Answers
A:The proposal fits Source-of-truth for intent automation — counterfactual B: Automation complexity should scale with actual inventory and integration needs. The present constraint is: Monitoring design must respect security zones and avoid interpreting intentional denial as failure. The relevant response is: Design dedicated permitted monitoring paths and authenticated observability consistent with segmentation.
B:This proposal matches the different constraint in OAM reachability across security zones — counterfactual B, where Device reachability is insufficient for detecting directional service impairment. Here, Monitoring design must respect security zones and avoid interpreting intentional denial as failure. The relevant response is Design dedicated permitted monitoring paths and authenticated observability consistent with segmentation. [Family R165-F038, scenario R165-C075, item R165-Q0371.]
C:The proposal fits IPv6 end-to-end access design — constraint A: An address-family rollout can create an unprotected parallel forwarding path. The present constraint is: Monitoring design must respect security zones and avoid interpreting intentional denial as failure. The relevant response is: Design dedicated permitted monitoring paths and authenticated observability consistent with segmentation.
Question 372
NOC probes for manufacturing devices originate from a blocked management subnet and repeatedly trigger false outage alarms. How should the architect validate the critical trade-off before broad rollout?
- Compare service health from authorized zone collectors and blocked NOC probes.
- Confirm the test prefix attributes and that production prefixes remain identical.
- Inject the prohibited prefix in a test session and observe deterministic rejection.
- Generate one-way loss while measuring source-to-destination and destination-to-source paths separately.
Explanation
Correct Answer
A:This check exercises the critical trade-off because Monitoring design must respect security zones and avoid interpreting intentional denial as failure. Its specific acceptance evidence is: Alerting reflects actual service availability without creating unrestricted management access. Design task 3.1.b requires evidence of actual behavior rather than only configuration presence. [Family R165-F038, scenario R165-C075, item R165-Q0372.]
Incorrect Answers
B:That check belongs to Rollback conditions on route-policy changes — counterfactual B: Change verification should follow actual reachability scope. Here, monitoring design must respect security zones and avoid interpreting intentional denial as failure. The decisive evidence is: Compare service health from authorized zone collectors and blocked NOC probes.
C:That check belongs to ML-based anomaly detection evidence — counterfactual B: Hard routing constraints need deterministic enforcement instead of statistical inference. Here, monitoring design must respect security zones and avoid interpreting intentional denial as failure. The decisive evidence is: Compare service health from authorized zone collectors and blocked NOC probes.
D:This check is valid for a different setting, OAM reachability across security zones — counterfactual B, because Device reachability is insufficient for detecting directional service impairment. In this scenario the discriminating evidence is Compare service health from authorized zone collectors and blocked NOC probes. because Monitoring design must respect security zones and avoid interpreting intentional denial as failure. [Family R165-F038, scenario R165-C075, item R165-Q0372.]
Question 373
NOC probes for manufacturing devices originate from a blocked management subnet and repeatedly trigger false outage alarms. Which measurable acceptance condition would support approving this design?
- Alerting reflects actual service availability without creating unrestricted management access.
- Monitoring identifies the asymmetric flow failure even while devices are pingable.
- Approved routes exchange without NAT or route overlap.
- Both address families enforce the same approved web protection.
Explanation
Correct Answer
A:The governing constraint is: Monitoring design must respect security zones and avoid interpreting intentional denial as failure. The action is: Design dedicated permitted monitoring paths and authenticated observability consistent with segmentation. Confirm with: Compare service health from authorized zone collectors and blocked NOC probes.
Incorrect Answers
B:This result would establish success for OAM reachability across security zones — counterfactual B, not the stated requirement. Here, Monitoring design must respect security zones and avoid interpreting intentional denial as failure. The measurable acceptance condition is Alerting reflects actual service availability without creating unrestricted management access. [Family R165-F038, scenario R165-C075, item R165-Q0373.]
C:This result would establish success for Overlapping IP during acquisition migration — counterfactual B, not the stated requirement. Here, Monitoring design must respect security zones and avoid interpreting intentional denial as failure. The measurable acceptance condition is Alerting reflects actual service availability without creating unrestricted management access.
D:This result would establish success for Dual-stack transition design — constraint A, not the stated requirement. Here, Monitoring design must respect security zones and avoid interpreting intentional denial as failure. The measurable acceptance condition is Alerting reflects actual service availability without creating unrestricted management access.
Question 374
NOC probes for manufacturing devices originate from a blocked management subnet and repeatedly trigger false outage alarms. What architectural mechanism is responsible for the risk in this case?
- Monitoring design must respect security zones and avoid interpreting intentional denial as failure.
- Physical control loops should not depend on nondeterministic long-distance L2 extension.
- Device reachability is insufficient for detecting directional service impairment.
- Many identical receivers favor efficient one-to-many delivery where multicast can be supported.
Explanation
Correct Answer
A:The observed case is: NOC probes for manufacturing devices originate from a blocked management subnet and repeatedly trigger false outage alarms. The corresponding action is: Design dedicated permitted monitoring paths and authenticated observability consistent with segmentation. Verify with: Compare service health from authorized zone collectors and blocked NOC probes.
Incorrect Answers
B:This would explain Industrial controllers use a deterministic time-critical layer-two protocol and engineers propose stretching the VLAN across distant cloud regions. but not NOC probes for manufacturing devices originate from a blocked management subnet and repeatedly trigger false outage alarms. The scenario instead states Monitoring design must respect security zones and avoid interpreting intentional denial as failure.
C:This would explain A corporate monitoring server can reach every router but cannot detect one-way forwarding drops across an interconnect. but not NOC probes for manufacturing devices originate from a blocked management subnet and repeatedly trigger false outage alarms. The scenario instead states Monitoring design must respect security zones and avoid interpreting intentional denial as failure.
D:This would explain A lecture stream is sent to 8,000 receivers on the same managed campus, causing identical unicast copies to saturate distribution links. but not NOC probes for manufacturing devices originate from a blocked management subnet and repeatedly trigger false outage alarms. The scenario instead states Monitoring design must respect security zones and avoid interpreting intentional denial as failure.
Question 375
NOC probes for manufacturing devices originate from a blocked management subnet and repeatedly trigger false outage alarms. Choose the TWO elements that belong in a defensible design decision and its review.
- Generate one-way loss while measuring source-to-destination and destination-to-source paths separately.
- Compare service health from authorized zone collectors and blocked NOC probes.
- Add directional synthetic probes and path telemetry rather than relying on ICMP router liveness.
- Design dedicated permitted monitoring paths and authenticated observability consistent with segmentation.
- Monitoring identifies the asymmetric flow failure even while devices are pingable.
Explanation
Correct Answers
B:Supported design and verification element: This check exercises the critical trade-off because Monitoring design must respect security zones and avoid interpreting intentional denial as failure. Its specific acceptance evidence is: Alerting reflects actual service availability without creating unrestricted management access. Design task 3.1.b requires evidence of actual behavior rather than only configuration presence. [Family R165-F038, scenario R165-C075, item R165-Q0375.]
D:Supported design and verification element: This decision addresses the governing constraint because Monitoring design must respect security zones and avoid interpreting intentional denial as failure. Verify using: Compare service health from authorized zone collectors and blocked NOC probes. The intended result is: Alerting reflects actual service availability without creating unrestricted management access. It maps to Cisco CCDE v3.1 task 3.1.b. [Family R165-F038, scenario R165-C075, item R165-Q0375.]
Incorrect Answers
A:This check is valid for a different setting, OAM reachability across security zones — counterfactual B, because Device reachability is insufficient for detecting directional service impairment. In this scenario the discriminating evidence is Compare service health from authorized zone collectors and blocked NOC probes. because Monitoring design must respect security zones and avoid interpreting intentional denial as failure. [Family R165-F038, scenario R165-C075, item R165-Q0375.]
C:This proposal matches the different constraint in OAM reachability across security zones — counterfactual B, where Device reachability is insufficient for detecting directional service impairment. Here, Monitoring design must respect security zones and avoid interpreting intentional denial as failure. The relevant response is Design dedicated permitted monitoring paths and authenticated observability consistent with segmentation. [Family R165-F038, scenario R165-C075, item R165-Q0375.]
E:This result would establish success for OAM reachability across security zones — counterfactual B, not the stated requirement. Here, Monitoring design must respect security zones and avoid interpreting intentional denial as failure. The measurable acceptance condition is Alerting reflects actual service availability without creating unrestricted management access. [Family R165-F038, scenario R165-C075, item R165-Q0375.]
Question 376
A corporate monitoring server can reach every router but cannot detect one-way forwarding drops across an interconnect. What is the best design choice for this precise situation?
- Use temporary policy-controlled translation or interconnect isolation while planning application migration and decommission.
- Design dedicated permitted monitoring paths and authenticated observability consistent with segmentation.
- Use scalable CDN/unicast adaptive delivery rather than assuming multicast across the public Internet.
- Add directional synthetic probes and path telemetry rather than relying on ICMP router liveness.
Explanation
Correct Answer
D:This decision addresses the governing constraint because Device reachability is insufficient for detecting directional service impairment. Verify using: Generate one-way loss while measuring source-to-destination and destination-to-source paths separately. The intended result is: Monitoring identifies the asymmetric flow failure even while devices are pingable. It maps to Cisco CCDE v3.1 task 3.1.b. [Family R165-F038, scenario R165-C076, item R165-Q0376.]
Incorrect Answers
A:The proposal fits Customer growth and address planning — counterfactual B: Short-lived overlapping assets may justify bounded transitional isolation rather than permanent redesign. The present constraint is: Device reachability is insufficient for detecting directional service impairment. The relevant response is: Add directional synthetic probes and path telemetry rather than relying on ICMP router liveness.
B:This proposal matches the different constraint in OAM reachability across security zones — constraint A, where Monitoring design must respect security zones and avoid interpreting intentional denial as failure. Here, Device reachability is insufficient for detecting directional service impairment. The relevant response is Add directional synthetic probes and path telemetry rather than relying on ICMP router liveness. [Family R165-F038, scenario R165-C076, item R165-Q0376.]
C:The proposal fits Multicast versus replicated unicast video — counterfactual B: Internet-wide multicast assumptions are not dependable for general SaaS delivery. The present constraint is: Device reachability is insufficient for detecting directional service impairment. The relevant response is: Add directional synthetic probes and path telemetry rather than relying on ICMP router liveness.
Question 377
A corporate monitoring server can reach every router but cannot detect one-way forwarding drops across an interconnect. How should the architect validate the critical trade-off before broad rollout?
- Compare service health from authorized zone collectors and blocked NOC probes.
- Generate one-way loss while measuring source-to-destination and destination-to-source paths separately.
- Demonstrate equivalent traffic policy and telemetry workflows on two representative platforms.
- Trace representative overlapping-IP flows through temporary boundary translation and exit milestones.
Explanation
Correct Answer
B:This check exercises the critical trade-off because Device reachability is insufficient for detecting directional service impairment. Its specific acceptance evidence is: Monitoring identifies the asymmetric flow failure even while devices are pingable. Design task 3.1.b requires evidence of actual behavior rather than only configuration presence. [Family R165-F038, scenario R165-C076, item R165-Q0377.]
Incorrect Answers
A:This check is valid for a different setting, OAM reachability across security zones — constraint A, because Monitoring design must respect security zones and avoid interpreting intentional denial as failure. In this scenario the discriminating evidence is Generate one-way loss while measuring source-to-destination and destination-to-source paths separately. because Device reachability is insufficient for detecting directional service impairment. [Family R165-F038, scenario R165-C076, item R165-Q0377.]
C:That check belongs to Vendor independence and feature portability — constraint A: Undocumented vendor-specific dependencies undermine a portability requirement. Here, device reachability is insufficient for detecting directional service impairment. The decisive evidence is: Generate one-way loss while measuring source-to-destination and destination-to-source paths separately.
D:That check belongs to Customer growth and address planning — counterfactual B: Short-lived overlapping assets may justify bounded transitional isolation rather than permanent redesign. Here, device reachability is insufficient for detecting directional service impairment. The decisive evidence is: Generate one-way loss while measuring source-to-destination and destination-to-source paths separately.
Question 378
A corporate monitoring server can reach every router but cannot detect one-way forwarding drops across an interconnect. Which observed outcome most directly confirms the proposed architecture?
- Monitoring identifies the asymmetric flow failure even while devices are pingable.
- Alerting reflects actual service availability without creating unrestricted management access.
- The branch stops blackholing when the only upstream route becomes unavailable.
- The lab restores predictably without introducing an unnecessary enterprise inventory platform.
Explanation
Correct Answer
A:This validates the outcome that matters: Device reachability is insufficient for detecting directional service impairment. The agreed action is Add directional synthetic probes and path telemetry rather than relying on ICMP router liveness. and the confirming method is Generate one-way loss while measuring source-to-destination and destination-to-source paths separately. (Cisco task 3.1.b). [Family R165-F038, scenario R165-C076, item R165-Q0378.]
Incorrect Answers
B:This result would establish success for OAM reachability across security zones — constraint A, not the stated requirement. Here, Device reachability is insufficient for detecting directional service impairment. The measurable acceptance condition is Monitoring identifies the asymmetric flow failure even while devices are pingable. [Family R165-F038, scenario R165-C076, item R165-Q0378.]
C:This result would establish success for BGP multihoming policy and predictability — counterfactual B, not the stated requirement. Here, Device reachability is insufficient for detecting directional service impairment. The measurable acceptance condition is Monitoring identifies the asymmetric flow failure even while devices are pingable.
D:This result would establish success for Source-of-truth for intent automation — counterfactual B, not the stated requirement. Here, Device reachability is insufficient for detecting directional service impairment. The measurable acceptance condition is Monitoring identifies the asymmetric flow failure even while devices are pingable.
Question 379
A corporate monitoring server can reach every router but cannot detect one-way forwarding drops across an interconnect. Which underlying requirement makes one design defensible and another unsafe?
- Device reachability is insufficient for detecting directional service impairment.
- Monitoring design must respect security zones and avoid interpreting intentional denial as failure.
- Small isolated systems do not require a complex enterprise wave schedule.
- Hard routing constraints need deterministic enforcement instead of statistical inference.
Explanation
Correct Answer
A:The observed case is: A corporate monitoring server can reach every router but cannot detect one-way forwarding drops across an interconnect. The corresponding action is: Add directional synthetic probes and path telemetry rather than relying on ICMP router liveness. Verify with: Generate one-way loss while measuring source-to-destination and destination-to-source paths separately.
Incorrect Answers
B:This would explain NOC probes for manufacturing devices originate from a blocked management subnet and repeatedly trigger false outage alarms. but not A corporate monitoring server can reach every router but cannot detect one-way forwarding drops across an interconnect. The scenario instead states Device reachability is insufficient for detecting directional service impairment.
C:This would explain An isolated lab segment can be rebuilt from known images and has no user traffic or downstream dependencies. but not A corporate monitoring server can reach every router but cannot detect one-way forwarding drops across an interconnect. The scenario instead states Device reachability is insufficient for detecting directional service impairment.
D:This would explain A deterministic routing invariant forbids advertisements of an internal RFC1918 prefix to an external peer. but not A corporate monitoring server can reach every router but cannot detect one-way forwarding drops across an interconnect. The scenario instead states Device reachability is insufficient for detecting directional service impairment.
Question 380
A corporate monitoring server can reach every router but cannot detect one-way forwarding drops across an interconnect. Which THREE statements are directly supported by the scenario and its technical evidence?
- Compare service health from authorized zone collectors and blocked NOC probes.
- Generate one-way loss while measuring source-to-destination and destination-to-source paths separately.
- Add directional synthetic probes and path telemetry rather than relying on ICMP router liveness.
- Monitoring identifies the asymmetric flow failure even while devices are pingable.
- Design dedicated permitted monitoring paths and authenticated observability consistent with segmentation.
- Alerting reflects actual service availability without creating unrestricted management access.
Explanation
Correct Answers
B:Supported design and verification element: This check exercises the critical trade-off because Device reachability is insufficient for detecting directional service impairment. Its specific acceptance evidence is: Monitoring identifies the asymmetric flow failure even while devices are pingable. Design task 3.1.b requires evidence of actual behavior rather than only configuration presence. [Family R165-F038, scenario R165-C076, item R165-Q0380.]
C:Supported design and verification element: This decision addresses the governing constraint because Device reachability is insufficient for detecting directional service impairment. Verify using: Generate one-way loss while measuring source-to-destination and destination-to-source paths separately. The intended result is: Monitoring identifies the asymmetric flow failure even while devices are pingable. It maps to Cisco CCDE v3.1 task 3.1.b. [Family R165-F038, scenario R165-C076, item R165-Q0380.]
D:Supported design and verification element: This validates the outcome that matters: Device reachability is insufficient for detecting directional service impairment. The agreed action is Add directional synthetic probes and path telemetry rather than relying on ICMP router liveness. and the confirming method is Generate one-way loss while measuring source-to-destination and destination-to-source paths separately. (Cisco task 3.1.b). [Family R165-F038, scenario R165-C076, item R165-Q0380.]
Incorrect Answers
A:This check is valid for a different setting, OAM reachability across security zones — constraint A, because Monitoring design must respect security zones and avoid interpreting intentional denial as failure. In this scenario the discriminating evidence is Generate one-way loss while measuring source-to-destination and destination-to-source paths separately. because Device reachability is insufficient for detecting directional service impairment. [Family R165-F038, scenario R165-C076, item R165-Q0380.]
E:This proposal matches the different constraint in OAM reachability across security zones — constraint A, where Monitoring design must respect security zones and avoid interpreting intentional denial as failure. Here, Device reachability is insufficient for detecting directional service impairment. The relevant response is Add directional synthetic probes and path telemetry rather than relying on ICMP router liveness. [Family R165-F038, scenario R165-C076, item R165-Q0380.]
F:This result would establish success for OAM reachability across security zones — constraint A, not the stated requirement. Here, Device reachability is insufficient for detecting directional service impairment. The measurable acceptance condition is Monitoring identifies the asymmetric flow failure even while devices are pingable. [Family R165-F038, scenario R165-C076, item R165-Q0380.]
Cisco Certified Design Expert (400-007) Practice Tests