100% Latest & Updated CompTIA SY0-701 Practice Test Questions, Exam Dumps & Verified Answers!
30 Days Free Updates, Instant Download!
Question 200
The backup console shows green completion icons for twelve months, but nobody has restored the online ordering system in a test environment. Which exercise provides useful evidence of recoverability?
- Remove expired logs from the monitoring console to improve appearance.
- Print a list of successful backup schedules without attempting recovery.
- Validate each backup archive checksum and storage-job status but never start the restored ordering application.
- Restore the service to an isolated test system and complete representative order processing.
Explanation
Correct Answer
D:A working order path proves the backup can support actual application recovery, not merely copied files. Restoring in isolation and successfully placing representative orders validates the backup media, required dependencies and application data path. Measure restoration time and compare it with the business recovery objective.
Incorrect Answers
A:Deleting observations weakens auditability without demonstrating the backup can run the ordering workflow. Deleting historical logs makes it harder to trace backup failures and does nothing to demonstrate that ordering transactions can be processed from recovered files. Monitoring appearance is not a recovery test.
B:A job can report success while storing incompatible or corrupted application data. A successful schedule may have copied bytes that cannot be decrypted, mounted or understood by the current application. Restoring and exercising the ordering workflow tests a stronger property than job completion.
C:Checksums can show that stored archive bytes have not changed, and backup-job logs show whether collection tasks completed. Neither demonstrates that the current ordering application can boot, interpret the restored schema, satisfy dependencies or process a real order. Recoverability must be exercised end-to-end in a safe test environment against an observable business transaction.
Question 201
A network controller must remain powered for 90 seconds while a standby generator starts. The measured controller load is 500 W. Which UPS acceptance criterion is relevant?
- Demonstrate UPS runtime longer than 90 seconds at the actual 500 W controller load.
- Increase the controller's network buffer and remove the UPS.
- Trust the generator's advertised start time without exercising the transfer under load.
- Choose any UPS whose packaging says 500 VA without reviewing power factor or runtime.
Explanation
Correct Answer
A:Measured load testing shows the controller can bridge generator start and transfer without losing power. Use the measured 500-watt operating draw, not a marketing nameplate, and demonstrate continuous output throughout engine cranking and automatic-transfer delay. A loaded discharge test should include battery aging and transfer tolerance so controller power never drops at the critical handoff.
Incorrect Answers
B:Packet buffering cannot keep electronic equipment energized after utility power disappears. A network buffer holds packets in memory only while the device has electrical power. Removing battery backup would make the controller reboot as soon as utility feed is lost; no amount of buffering bridges the generator's 90-second start interval.
C:A generator promise does not prove the battery covers worst-case startup and switching delay. A generator may start late, fail its automatic transfer or experience a voltage dip while accepting load. The UPS must carry the controller across the entire sequence, which can only be established by a timed exercise under representative electrical demand.
D:Volt-ampere labeling alone does not establish the necessary wattage or 90-second autonomy. Five hundred volt-amperes describes apparent power, not necessarily a guaranteed 500-watt capacity, and says nothing about battery autonomy. Review the UPS output rating and runtime curve at 500 W, then verify acceptable transfer behavior in a loaded test.
Question 202
A backup generator starts successfully in every short test, but a regional outage could last four days and the contracted fuel supplier closes after one day. What resilience question is missing?
- Remove every fuel gauge because the engine ran once.
- Add more office laptops without increasing generation capacity.
- Validate load endurance and obtain dependable fuel replenishment for a multiday interruption.
- Treat a 30-second successful start test as evidence of four-day autonomy.
Explanation
Correct Answer
C:The generator is useful only while its power output can be sustained over the specified recovery window. Model actual consumption under the site's expected emergency load, inspect stored fuel and maintenance availability, and confirm a supplier or reserve that remains operable during a regional disruption. A four-day plan needs endurance evidence, not just successful ignition.
Incorrect Answers
A:Losing fuel-status evidence makes extended operation less predictable and harder to manage. Fuel indication is essential to forecast how long the installed tank will support the generator's real electrical load. Removing instrumentation would hide declining reserves and prevent responders from arranging emergency delivery before electrical service stops.
B:Extra electrical load could reduce endurance and offers no fuel supply assurance. Laptops are downstream consumers of power, not a replacement for fuel reserves. Adding them may increase generator demand and shorten its operating window, while the supplier's one-day closure still leaves a multiday replenishment gap.
D:Ignition does not demonstrate fuel reserves, serviceability or refueling arrangements over several days. A brief ignition exercise establishes only that starting components worked under those conditions. It does not test extended fuel availability, sustained cooling, maintenance failures or the availability of operators and supply deliveries during a four-day outage.
Question 203
A warm recovery site contains spare servers but licenses support only half the ordinary customer traffic. What planning step ensures the recovered service can handle required demand?
- Test recovery-site throughput against representative demand and provision missing licenses and capacity.
- Assume demand will disappear during an outage because the site is called warm.
- Count server chassis without evaluating licensed application limits.
- Hide queue-length monitoring to make the failover dashboard simpler.
Explanation
Correct Answer
A:A powered standby that cannot handle business volume does not meet the expected continuity requirement. Load-test the complete application stack at failover, including license-enforced concurrent sessions and peak transaction rates. If licensing caps usage at half demand, additional physical servers will not fix the contractual or software entitlement ceiling without procurement and verification.
Incorrect Answers
B:Business functions often need the alternate location most when the primary environment fails. A warm site exists to preserve essential business functions when demand may be unusually high, not to remove those functions. Assuming half the customers will disappear conceals the real service-level shortfall and leaves no evidence of acceptable queuing or response times.
C:Hardware inventory alone may conceal a software constraint that prevents handling actual workloads. The server count measures physical inventory while licensing can throttle connections, cores or transaction throughput. An application limited to half the ordinary workload can violate continuity requirements even with surplus CPU and correctly restored databases.
D:Removing load signals obscures whether the alternate site can serve transactions within policy. Removing queue metrics only makes overload harder to diagnose and cannot increase actual processing capacity. Monitor response time, failed sessions and queue growth during a representative failover to establish whether business volume can be sustained.
Question 204
Two storage backups are kept on different shelves within one facility that floods whenever the nearby river breaches. What additional redundancy dimension is missing?
- Move the second copy to another cabinet in the same flooded room.
- Name the local copies primary and secondary in the asset catalog.
- Increase the second shelf's storage capacity without relocating it.
- Replicate protected data to a tested offsite region not exposed to the same flood.
Explanation
Correct Answer
D:An independent location lets recovery proceed even when the local facility and all its shelves are inaccessible. Put a protected copy in a geographically independent failure domain, confirm its encryption/key access and test restoration when the primary site is unavailable. The key requirement is that one flood cannot eliminate both recovery options, not merely that replicas exist.
Incorrect Answers
A:Cabinet separation cannot survive a common building-wide flood. Another cabinet shares the same floodplain, power circuits and building access. When river water closes the facility, both copies are inaccessible, so cabinet separation offers no meaningful protection against the named common-cause event.
B:Administrative labels do not change their shared geographic exposure. Primary and secondary are inventory roles rather than failure domains. Renaming the copies does not change that a single river breach can simultaneously damage both storage locations and block access to either during recovery.
C:More local capacity remains vulnerable to the same environmental disaster. Additional storage within the same flood-threatened room protects against capacity shortage, not the specified environmental event. A larger second shelf still cannot supply usable backup data if the entire building is submerged or evacuated.
Question 205
An executive incident team has a written regional-outage plan, but role owners repeatedly argue about who may declare failover. What rehearsal addresses decision coordination before an actual incident?
- Wait for a real disaster to discover missing roles.
- Perform only a router throughput benchmark.
- Conduct a tabletop using timed outage injects and require each role to demonstrate its decision.
- Rename all participants to a single shared incident account.
Explanation
Correct Answer
C:A realistic scenario exposes unclear declaration authority without risking live production systems. Present a realistic timed outage and require each decision-maker to demonstrate trigger, authority, escalation and communications. Record disagreements, revise the incident command matrix and repeat the exercise until failover can be declared without conflicting approvals.
Incorrect Answers
A:Learning during a regional outage can delay recovery and compound business impact. Waiting for a live catastrophe makes a governance dispute part of the real recovery path, delaying the decision that starts technical failover. Unresolved declaration rights should be exercised safely before a business-critical deadline is at stake.
B:Network capacity testing cannot resolve executive decision ownership or crisis communication. A throughput test can prove that a router handles packets under load but cannot reveal who authorizes a regional cutover or which executive informs stakeholders. The problem is decision ownership and escalation, not link capacity.
D:Removing personal attribution makes responsibility for declarations even less clear. A shared identity hides the individual who actually made a declaration and weakens accountability. Recovery exercises need named decision owners with deputies and a recorded escalation path, not an account that makes everyone's authority indistinguishable.
Question 206
During a failover rehearsal, responders discover that the runbook directs traffic to DNS addresses retired six months ago. What should continuity management do?
- Revise the DNS steps and repeat the cutover in a controlled exercise.
- Delete the entire recovery plan to avoid keeping obsolete data.
- Assume the old records will work because the printed guide is signed.
- Run network reachability checks against the old recovery DNS addresses without revising the steps in the failover runbook.
Explanation
Correct Answer
A:Testing the corrected sequence confirms that responders can direct clients to the real alternate service. Update the runbook with validated current target addresses, resolver dependencies, cache/TTL behavior and an owner for keeping the steps current. Then perform a cutover to prove clients actually resolve and reach the alternate service, not merely that the edit was saved.
Incorrect Answers
B:Removing guidance without a replacement creates greater confusion than a verified update. A damaged instruction is evidence of a maintenance defect, not proof that all recovery guidance should disappear. Delete-only action leaves responders without a cutover sequence, increasing the chance of improvisation and further outages.
C:Document approval does not guarantee that stale addresses still reach available systems. Approval signatures establish historical authorization, not ongoing DNS correctness. Decommissioned records may no longer resolve or may point elsewhere, so the signed instructions must be reconciled with live configurations and tested end to end.
D:A reachability check may confirm whether one retired address still responds, but it leaves the written restoration procedure pointing to stale infrastructure. Future responders could follow the same obsolete records and fail again. Continuity management must update the actual DNS instructions and then demonstrate the corrected cutover in a controlled rehearsal.
Question 207
An emergency support portal cannot start until both customer identity and DNS services are recovered. The existing plan tries to restore the portal first. What sequencing change is necessary?
- Hide service errors from operators until all systems start.
- Prioritize only nonessential reporting dashboards because they have simpler recovery scripts.
- Restore and validate identity and DNS services before switching customer support traffic.
- Restart the portal repeatedly while leaving identity and DNS unavailable.
Explanation
Correct Answer
C:The application cannot authenticate users or resolve dependencies until the prerequisite services function. Bring up DNS resolution and the relevant identity service, validate actual lookup and login transactions, and only then route customers to the portal. This sequence addresses the mandatory prerequisites that were keeping a running portal process unusable.
Incorrect Answers
A:Suppressing failures delays discovery of the dependency-order problem. Hiding the portal's authentication and name-resolution errors does not make either prerequisite operational. It removes the diagnostic signals needed to identify which dependency must be restored first and lengthens time to usable customer access.
B:Easy workloads do not restore the prerequisite services the critical portal needs. Reporting dashboards may recover quickly, but their simplicity does not make them prerequisites of the customer support portal. Recovery order should follow the service dependency graph and business priority, not whichever isolated process is easiest to restart.
D:Repetition cannot satisfy external dependencies that remain offline. Repeated application restarts do not create valid DNS records or provide authentication tokens when the respective services are offline. It may also add needless load and confusing events during incident response rather than repairing the dependency chain.
Question 208
A recovery team claims it can restore a claims service within one hour, but the claim comes from a spreadsheet estimate rather than an actual exercise. What measurement is necessary?
- Replace timing evidence with a confidence statement from leadership.
- Count only the number of people on the recovery roster.
- Perform timed restoration trials and record both service availability and committed-data loss.
- Time how quickly the recovery VM boots and responds to ICMP pings, without testing the claims application or recovered transactions.
Explanation
Correct Answer
C:The one-hour recovery claim is a hypothesis until the service is actually restored under realistic dependencies. Start timing when the simulated outage begins, then measure when an end-to-end claims transaction succeeds and how old the newest recovered committed record is. These observations establish practical recovery time and recovery point rather than repeating the planning spreadsheet’s promised figures.
Incorrect Answers
A:Assurance without measurement cannot demonstrate compliance with a defined one-hour restoration target. Leadership may reasonably express confidence, but it provides no observation of application start, dependent database readiness or a successfully completed claims transaction. Timed service-level evidence is necessary to support an objective stated as one hour.
B:Staffing numbers cannot establish how long the dependent claims workflow takes to return. Personnel headcount can contribute to planning but does not measure network propagation, database restoration or application integrity. A large on-call roster may still need hours to return the real claims workflow to usable service.
D:Boot completion and network reachability are measurable elements of a recovery exercise, so this proposal is more credible than a spreadsheet estimate. They do not show that application dependencies are healthy, users can process claims or the restored data satisfy the loss objective. A timed end-to-end service restoration test must measure those business outcomes.
Question 209
A batch of company laptops arrives with unrestricted local administrator accounts and permissive browser settings. What must provisioning complete before users receive the devices?
- Keep local administrator access to make every support request easier.
- Enforce a managed hardening image that removes unnecessary admin rights and insecure defaults.
- Ask users to harden their own devices after the first security incident.
- Disable configuration compliance reporting after shipping.
Explanation
Correct Answer
B:Preassignment configuration closes predictable entry paths before the employee starts using the laptop. A centrally managed image should remove superfluous administrators, enforce browser protections, apply patches and verify compliance before assignment. This gives each laptop a defined starting security posture rather than relying on employees to correct dangerous default settings later.
Incorrect Answers
A:Universal elevation enables unwanted software installation and magnifies compromise impact. Leaving local administrator privileges widely available lets malicious code install drivers or disable protections with little resistance. Support convenience is not a sufficient reason to expose every delivered device to unnecessary escalation capability.
C:Delayed voluntary action leaves known dangerous defaults exposed during normal operation. The defect exists before the first login, so waiting for an incident knowingly exposes the fleet. Many insecure defaults are invisible to users, and personal initiative cannot substitute for a repeatable provisioning acceptance check.
D:Missing telemetry conceals drift and cannot establish that each device met the baseline. Compliance reporting tells the security team whether a device has drifted or missed the approved baseline. Disabling it after shipment undermines evidence that local privilege and browser settings remain controlled as users install and update software.
Question 210
Web servers run unused remote services and share a local root password. Which hardening package most directly limits the resulting attack surface?
- Disable unused daemons, require named privileged identities and verify the hardened configuration.
- Keep the shared root secret and rotate only the browser theme.
- Add server RAM while leaving all services and root access unchanged.
- Restrict internet-facing router ports with perimeter ACLs while leaving unused local server daemons and the shared root password unchanged.
Explanation
Correct Answer
A:Fewer exposed listeners and accountable administration limit both entry paths and unchecked high-privilege changes. Rotating a shared root password does not distinguish which engineer used it, and browser appearance cannot remove exposed network listeners. Intruders could still target unused daemons and operate with administrator privileges once they gain the shared secret.
Incorrect Answers
B:Interface appearance cannot separate administrators or remove vulnerable remote daemons. Turn off unnecessary listeners, apply least privilege with individual admin identities and retain audit trails. Baseline testing should confirm that required web service functionality remains operational while redundant remote access and unmanaged root sessions are no longer exposed.
C:Capacity improvement does not reduce attack reachability or credential-sharing risk. More memory can improve legitimate transaction capacity but leaves network-facing services and credential-sharing practices unchanged. Attackers do not require a resource shortage to exploit an exposed management service or reuse a privileged secret.
D:Perimeter ACLs can narrow remote entry points and are a legitimate layer of defense. But an attacker who reaches a server through another route still encounters the unnecessary listening services and a non-attributable shared root credential. The stated server-hardening task requires reducing the local service surface and replacing shared privileged access, not only upstream filtering.
CompTIA Security+ (SY0-701) Practice Tests