Fortinet NSE5_FSW_AD-7.6 Practice Test 21

Question 200

A fiber link reports unstable negotiation, CRC errors, and low received light. Choose THREE physical-layer checks.

  1. CRC and FCS error counters
  2. Optical receive power
  3. Port administrative enable
  4. VLAN port membership
  5. LACP member state
  6. Speed and duplex negotiation

Explanation

Correct Answers

A:

Ethernet negotiation, frame errors and optical power are complementary physical diagnostics. CRC or FCS errors can reveal corrupted frames related to physical media or duplex problems.

B:

Ethernet negotiation, frame errors and optical power are complementary physical diagnostics. Optic diagnostics help identify receive-power levels outside supported transceiver specifications.

F:

Ethernet negotiation, frame errors and optical power are complementary physical diagnostics. Compatible link speed and duplex settings are needed on both ends for stable Ethernet communication.

Incorrect Answers

C:

A switch interface must be administratively enabled for normal forwarding and physical link operation. Here it is a different control and will not directly verify link mode, corruption counts and optic receive signal.

D:

Allowed and native VLAN choices determine network segmentation once the physical Ethernet link functions. This is not sufficient to verify link mode, corruption counts and optic receive signal.

E:

LACP state determines whether an eligible link participates in a negotiated aggregate. That does not establish the specific requirement to verify link mode, corruption counts and optic receive signal.

Question 201

A 60W powered camera fails on a port whose supported PoE class can deliver only 30W. Which limit prevents operation?

  1. Supported transceiver model
  2. Optical reach and loss budget
  3. Ethernet port density
  4. Per-port PoE class capability

Explanation

Correct Answer

D:

Port-specific PoE capability cannot deliver the device's negotiated power. An Ethernet access port must support the required negotiated PoE standard and power class of its attached device.

Incorrect Answers

A:

Optical modules must be compatible with the FortiSwitch model, target port speed and medium. For this scenario it cannot by itself support the higher power requirement on that single port.

B:

Transceiver reach and receive-power specifications must accommodate the actual fiber attenuation and distance. Here it is a different control and will not directly support the higher power requirement on that single port.

C:

A switch must have enough correctly typed physical ports for the expected endpoints and growth. This is not sufficient to support the higher power requirement on that single port.

Question 202

A closet has enough PoE-capable ports but their devices draw 720W while the chassis budget is 500W. Which limit is exceeded?

  1. Supported transceiver model
  2. Per-port PoE class capability
  3. Ethernet port density
  4. Total switch PoE budget

Explanation

Correct Answer

D:

Aggregate available PoE wattage must cover simultaneous endpoint demand. The switch's available aggregate PoE wattage must cover simultaneously powered endpoints within platform limits.

Incorrect Answers

A:

Optical modules must be compatible with the FortiSwitch model, target port speed and medium. Here it is a different control and will not directly power all connected devices concurrently.

B:

An Ethernet access port must support the required negotiated PoE standard and power class of its attached device. This is not sufficient to power all connected devices concurrently.

C:

A switch must have enough correctly typed physical ports for the expected endpoints and growth. That does not establish the specific requirement to power all connected devices concurrently.

Question 203

An installer inserts an unsupported optical module whose SKU is missing from the switch compatibility list. Which check comes first?

  1. Per-port PoE class capability
  2. Total switch PoE budget
  3. Supported transceiver model
  4. Ethernet port density

Explanation

Correct Answer

C:

Transceiver support must be validated against the model and port. Optical modules must be compatible with the FortiSwitch model, target port speed and medium.

Incorrect Answers

A:

An Ethernet access port must support the required negotiated PoE standard and power class of its attached device. This is not sufficient to install a supported compatible optical module.

B:

The switch's available aggregate PoE wattage must cover simultaneously powered endpoints within platform limits. That does not establish the specific requirement to install a supported compatible optical module.

D:

A switch must have enough correctly typed physical ports for the expected endpoints and growth. Here it is a different control and will not directly install a supported compatible optical module.

Question 204

A single-mode link spans more than its short-reach optical module's rated range. What must the design account for?

  1. Ethernet port density
  2. Uplink bandwidth capacity
  3. Per-port PoE class capability
  4. Optical reach and loss budget

Explanation

Correct Answer

D:

The optical reach and receive-power budget must match the actual route. Transceiver reach and receive-power specifications must accommodate the actual fiber attenuation and distance.

Incorrect Answers

A:

A switch must have enough correctly typed physical ports for the expected endpoints and growth. That does not establish the specific requirement to carry Ethernet over the required optical distance.

B:

Uplink speed and aggregation capacity must support expected aggregate throughput rather than only access port count. For this scenario it cannot by itself carry Ethernet over the required optical distance.

C:

An Ethernet access port must support the required negotiated PoE standard and power class of its attached device. Here it is a different control and will not directly carry Ethernet over the required optical distance.

Question 205

A new room adds 40 phones to a switch with only 24 usable access ports. Which resource is insufficient?

  1. Supported transceiver model
  2. Optical reach and loss budget
  3. Ethernet port density
  4. Total switch PoE budget

Explanation

Correct Answer

C:

The physical endpoint count exceeds installed port capacity. A switch must have enough correctly typed physical ports for the expected endpoints and growth.

Incorrect Answers

A:

Optical modules must be compatible with the FortiSwitch model, target port speed and medium. For this scenario it cannot by itself attach the required number of wired clients.

B:

Transceiver reach and receive-power specifications must accommodate the actual fiber attenuation and distance. Here it is a different control and will not directly attach the required number of wired clients.

D:

The switch's available aggregate PoE wattage must cover simultaneously powered endpoints within platform limits. That does not establish the specific requirement to attach the required number of wired clients.

Question 206

A lab has 48 fast endpoints feeding one heavily oversubscribed 1G uplink. Which bottleneck matters?

  1. Per-port PoE class capability
  2. Uplink bandwidth capacity
  3. Ethernet port density
  4. Supported transceiver model

Explanation

Correct Answer

B:

Uplink aggregate capacity must handle simultaneous traffic demand. Uplink speed and aggregation capacity must support expected aggregate throughput rather than only access port count.

Incorrect Answers

A:

An Ethernet access port must support the required negotiated PoE standard and power class of its attached device. Here it is a different control and will not directly avoid uplink congestion during peak aggregate throughput.

C:

A switch must have enough correctly typed physical ports for the expected endpoints and growth. That does not establish the specific requirement to avoid uplink congestion during peak aggregate throughput.

D:

Optical modules must be compatible with the FortiSwitch model, target port speed and medium. For this scenario it cannot by itself avoid uplink congestion during peak aggregate throughput.

Question 207

A wireless AP requests a higher power class than its interface supports despite unused overall chassis watts. Which check resolves it?

  1. Uplink bandwidth capacity
  2. Ethernet port density
  3. Supported transceiver model
  4. Per-port PoE class capability

Explanation

Correct Answer

D:

Per-port negotiation cannot be overridden by free chassis budget. An Ethernet access port must support the required negotiated PoE standard and power class of its attached device.

Incorrect Answers

A:

Uplink speed and aggregation capacity must support expected aggregate throughput rather than only access port count. This is not sufficient to deliver the AP's required per-interface PoE standard.

B:

A switch must have enough correctly typed physical ports for the expected endpoints and growth. That does not establish the specific requirement to deliver the AP's required per-interface PoE standard.

C:

Optical modules must be compatible with the FortiSwitch model, target port speed and medium. For this scenario it cannot by itself deliver the AP's required per-interface PoE standard.

Question 208

Thirty phones consume 12W each and fifteen APs need 24W each; the access stack has only 650W available for PoE. Which budget should be revisited?

  1. Supported transceiver model
  2. Uplink bandwidth capacity
  3. Optical reach and loss budget
  4. Total switch PoE budget

Explanation

Correct Answer

D:

The total 720W demand exceeds 650W available, absent any reserve. The switch's available aggregate PoE wattage must cover simultaneously powered endpoints within platform limits.

Incorrect Answers

A:

Optical modules must be compatible with the FortiSwitch model, target port speed and medium. That does not establish the specific requirement to size concurrent endpoint power requirements.

B:

Uplink speed and aggregation capacity must support expected aggregate throughput rather than only access port count. For this scenario it cannot by itself size concurrent endpoint power requirements.

C:

Transceiver reach and receive-power specifications must accommodate the actual fiber attenuation and distance. Here it is a different control and will not directly size concurrent endpoint power requirements.

Question 209

A high-power AP cannot negotiate its required per-port class and the closet's aggregate PoE budget is also exhausted. Choose TWO constraints.

  1. Ethernet port density
  2. Supported transceiver model
  3. Total switch PoE budget
  4. Optical reach and loss budget
  5. Per-port PoE class capability

Explanation

Correct Answers

C:

Port-level PoE support and chassis-wide wattage are independently limiting. The switch's available aggregate PoE wattage must cover simultaneously powered endpoints within platform limits.

E:

Port-level PoE support and chassis-wide wattage are independently limiting. An Ethernet access port must support the required negotiated PoE standard and power class of its attached device.

Incorrect Answers

A:

A switch must have enough correctly typed physical ports for the expected endpoints and growth. For this scenario it cannot by itself check per-port class and total power resource.

B:

Optical modules must be compatible with the FortiSwitch model, target port speed and medium. Here it is a different control and will not directly check per-port class and total power resource.

D:

Transceiver reach and receive-power specifications must accommodate the actual fiber attenuation and distance. That does not establish the specific requirement to check per-port class and total power resource.

Question 210

An interbuilding uplink needs supported optics, enough light budget and sufficient aggregate bandwidth. Choose THREE planning checks.

  1. Ethernet port density
  2. Supported transceiver model
  3. Uplink bandwidth capacity
  4. Optical reach and loss budget
  5. Total switch PoE budget
  6. Per-port PoE class capability

Explanation

Correct Answers

B:

Transceiver compatibility, optical reach and uplink throughput are separate prerequisites. Optical modules must be compatible with the FortiSwitch model, target port speed and medium.

C:

Transceiver compatibility, optical reach and uplink throughput are separate prerequisites. Uplink speed and aggregation capacity must support expected aggregate throughput rather than only access port count.

D:

Transceiver compatibility, optical reach and uplink throughput are separate prerequisites. Transceiver reach and receive-power specifications must accommodate the actual fiber attenuation and distance.

Incorrect Answers

A:

A switch must have enough correctly typed physical ports for the expected endpoints and growth. Here it is a different control and will not directly validate module support, fiber performance and capacity.

E:

The switch's available aggregate PoE wattage must cover simultaneously powered endpoints within platform limits. Here it is a different control and will not directly validate module support, fiber performance and capacity.

F:

An Ethernet access port must support the required negotiated PoE standard and power class of its attached device. This is not sufficient to validate module support, fiber performance and capacity.

Fortinet NSE 5 - FortiSwitch 7.6 Administrator (NSE5_FSW_AD-7.6) Practice Tests

UP

SPECIAL OFFER: GET 10% OFF

This is ONE TIME OFFER

ExamSnap Discount Offer
Enter Your Email Address to Receive Your 10% Off Discount Code

A confirmation link will be sent to this email address to verify your login. *We value your privacy. We will not rent or sell your email address.

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.