A routed FortiLink pilot has adequate IP reachability but an undiscovered, unapproved switch. Choose THREE relevant concepts.

  1. Provider VLAN service validation
  2. Local FortiLink physical connection
  3. FortiGate switch authorization
  4. Managed switch discovery traffic
  5. FortiLink over Layer 3
  6. Point-to-point Layer 2 FortiLink

Explanation

Correct Answers

C:

Layer 3 FortiLink design, discovery and authorization must all be satisfied. The FortiGate must approve the discovered switch for central FortiLink management.

D:

Layer 3 FortiLink design, discovery and authorization must all be satisfied. Discovery and switch management require an appropriate reachable control path between FortiGate and the FortiSwitch.

E:

Layer 3 FortiLink design, discovery and authorization must all be satisfied. Supported FortiLink over L3 uses routed reachability rather than relying solely on one bridged segment.

Incorrect Answers

A:

Intervening Layer 2 infrastructure must carry the required service VLANs and preserve the intended bridge domain. Here it is a different control and will not directly select routed management, ensure discovery and approve the device.

B:

A direct Ethernet FortiLink cable connects FortiGate and FortiSwitch without an intervening L2 service. This is not sufficient to select routed management, ensure discovery and approve the device.

F:

A supported dedicated Layer 2 transport can extend the FortiLink connection between FortiGate and a remote managed switch. This is not sufficient to select routed management, ensure discovery and approve the device.

Question 311

A controller must manage a FortiSwitch across two routers instead of the same VLAN. Which FortiLink deployment should be examined?

  1. FortiLink over Layer 3 capability
  2. Firewall policy reachability
  3. Layer 2 direct attachment
  4. Routed IP reachability

Explanation

Correct Answer

A:

The documented L3 FortiLink model supports routed controller-to-switch reachability. A supported FortiLink-over-L3 deployment manages remote switches through an IP-routed network under documented requirements.

Incorrect Answers

B:

When traffic traverses firewalls, approved policies must permit the required management sessions. That does not establish the specific requirement to manage a remote switch through routed network hops.

C:

A direct bridged FortiLink path does not by itself address management through intermediate IP routers. For this scenario it cannot by itself manage a remote switch through routed network hops.

D:

Network-layer routes must carry traffic between the required FortiGate and FortiSwitch control endpoints. Here it is a different control and will not directly manage a remote switch through routed network hops.

Question 312

A supported routed FortiLink design has no route back from the switch network to FortiGate. What must be fixed?

  1. Layer 2 direct attachment
  2. FortiLink over Layer 3 capability
  3. FortiLink controller authorization
  4. Routed IP reachability

Explanation

Correct Answer

D:

The return IP path is required for management communications. Network-layer routes must carry traffic between the required FortiGate and FortiSwitch control endpoints.

Incorrect Answers

A:

A direct bridged FortiLink path does not by itself address management through intermediate IP routers. That does not establish the specific requirement to provide bidirectional routing between management endpoints.

B:

A supported FortiLink-over-L3 deployment manages remote switches through an IP-routed network under documented requirements. For this scenario it cannot by itself provide bidirectional routing between management endpoints.

C:

The FortiGate must authorize the discovered or added switch before centrally pushing its managed configuration. Here it is a different control and will not directly provide bidirectional routing between management endpoints.

Question 313

A remote switch boots but has no valid IP settings to reach its L3 FortiLink manager. Which prerequisite is absent?

  1. Firewall policy reachability
  2. Address assignment
  3. Routed IP reachability
  4. Layer 2 direct attachment

Explanation

Correct Answer

B:

Address parameters are necessary for IP-based management reachability. Relevant managed endpoints need suitable IP address parameters to participate in a routed management path.

Incorrect Answers

A:

When traffic traverses firewalls, approved policies must permit the required management sessions. For this scenario it cannot by itself give the switch suitable L3 addressing information.

C:

Network-layer routes must carry traffic between the required FortiGate and FortiSwitch control endpoints. This is not sufficient to give the switch suitable L3 addressing information.

D:

A direct bridged FortiLink path does not by itself address management through intermediate IP routers. That does not establish the specific requirement to give the switch suitable L3 addressing information.

Question 314

The FortiGate can reach the remote switch, which is discovered but not adopted. What control-plane step remains?

  1. Address assignment
  2. Routed IP reachability
  3. FortiLink controller authorization
  4. Layer 2 direct attachment

Explanation

Correct Answer

C:

Authorization permits central configuration of an accepted FortiSwitch. The FortiGate must authorize the discovered or added switch before centrally pushing its managed configuration.

Incorrect Answers

A:

Relevant managed endpoints need suitable IP address parameters to participate in a routed management path. Here it is a different control and will not directly approve a discovered remote device.

B:

Network-layer routes must carry traffic between the required FortiGate and FortiSwitch control endpoints. This is not sufficient to approve a discovered remote device.

D:

A direct bridged FortiLink path does not by itself address management through intermediate IP routers. For this scenario it cannot by itself approve a discovered remote device.

Question 315

Routes exist but a firewall denies the relevant controller session from the switch subnet. Which control should be examined?

  1. FortiLink over Layer 3 capability
  2. Firewall policy reachability
  3. Address assignment
  4. Layer 2 direct attachment

Explanation

Correct Answer

B:

Permitted management flow is required across the firewall boundary. When traffic traverses firewalls, approved policies must permit the required management sessions.

Incorrect Answers

A:

A supported FortiLink-over-L3 deployment manages remote switches through an IP-routed network under documented requirements. This is not sufficient to allow the necessary FortiLink-over-L3 control traffic.

C:

Relevant managed endpoints need suitable IP address parameters to participate in a routed management path. For this scenario it cannot by itself allow the necessary FortiLink-over-L3 control traffic.

D:

A direct bridged FortiLink path does not by itself address management through intermediate IP routers. Here it is a different control and will not directly allow the necessary FortiLink-over-L3 control traffic.

Question 316

The engineer proposes only an untagged Layer 2 cable to solve a multi-router management path. What option is inadequate?

  1. FortiLink controller authorization
  2. Layer 2 direct attachment
  3. FortiLink over Layer 3 capability
  4. Routed IP reachability

Explanation

Correct Answer

B:

Simple direct attachment does not replace documented routed FortiLink support. A direct bridged FortiLink path does not by itself address management through intermediate IP routers.

Incorrect Answers

A:

The FortiGate must authorize the discovered or added switch before centrally pushing its managed configuration. That does not establish the specific requirement to manage across multiple routed hops.

C:

A supported FortiLink-over-L3 deployment manages remote switches through an IP-routed network under documented requirements. Here it is a different control and will not directly manage across multiple routed hops.

D:

Network-layer routes must carry traffic between the required FortiGate and FortiSwitch control endpoints. This is not sufficient to manage across multiple routed hops.

Question 317

A campus uses IP WAN transport for its remote FortiSwitch rather than extending a VLAN. Which documented architecture fits?

  1. FortiLink controller authorization
  2. FortiLink over Layer 3 capability
  3. Layer 2 direct attachment
  4. Firewall policy reachability

Explanation

Correct Answer

B:

FortiLink over Layer 3 handles a routed management topology. A supported FortiLink-over-L3 deployment manages remote switches through an IP-routed network under documented requirements.

Incorrect Answers

A:

The FortiGate must authorize the discovered or added switch before centrally pushing its managed configuration. For this scenario it cannot by itself avoid requiring an end-to-end common L2 broadcast domain.

C:

A direct bridged FortiLink path does not by itself address management through intermediate IP routers. This is not sufficient to avoid requiring an end-to-end common L2 broadcast domain.

D:

When traffic traverses firewalls, approved policies must permit the required management sessions. That does not establish the specific requirement to avoid requiring an end-to-end common L2 broadcast domain.

Question 318

The forward route to a remote switch exists but replies return to an unused default route. Which dependency explains failure?

  1. Routed IP reachability
  2. FortiLink controller authorization
  3. Firewall policy reachability
  4. Layer 2 direct attachment

Explanation

Correct Answer

A:

Management sessions need valid forward and reverse routes. Network-layer routes must carry traffic between the required FortiGate and FortiSwitch control endpoints.

Incorrect Answers

B:

The FortiGate must authorize the discovered or added switch before centrally pushing its managed configuration. This is not sufficient to complete the reverse IP route for the control session.

C:

When traffic traverses firewalls, approved policies must permit the required management sessions. That does not establish the specific requirement to complete the reverse IP route for the control session.

D:

A direct bridged FortiLink path does not by itself address management through intermediate IP routers. For this scenario it cannot by itself complete the reverse IP route for the control session.

Question 319

A remote FortiLink connection crosses routers and a filtering firewall. Choose TWO network requirements.

  1. Routed IP reachability
  2. FortiLink controller authorization
  3. Firewall policy reachability
  4. Layer 2 direct attachment
  5. Address assignment

Explanation

Correct Answers

A:

Bidirectional IP routing and permissive approved firewall policy are necessary. Network-layer routes must carry traffic between the required FortiGate and FortiSwitch control endpoints.

C:

Bidirectional IP routing and permissive approved firewall policy are necessary. When traffic traverses firewalls, approved policies must permit the required management sessions.

Incorrect Answers

B:

The FortiGate must authorize the discovered or added switch before centrally pushing its managed configuration. That does not establish the specific requirement to provide routed reachability and permit the control flows.

D:

A direct bridged FortiLink path does not by itself address management through intermediate IP routers. Here it is a different control and will not directly provide routed reachability and permit the control flows.

E:

Relevant managed endpoints need suitable IP address parameters to participate in a routed management path. This is not sufficient to provide routed reachability and permit the control flows.

Question 320

An IP-connected managed switch needs the supported L3 FortiLink mode, valid addressing and FortiGate authorization. Choose THREE ingredients.

  1. FortiLink over Layer 3 capability
  2. Address assignment
  3. Firewall policy reachability
  4. Routed IP reachability
  5. FortiLink controller authorization
  6. Layer 2 direct attachment

Explanation

Correct Answers

A:

Routed FortiLink support, addressing and authorization jointly enable adoption. A supported FortiLink-over-L3 deployment manages remote switches through an IP-routed network under documented requirements.

B:

Routed FortiLink support, addressing and authorization jointly enable adoption. Relevant managed endpoints need suitable IP address parameters to participate in a routed management path.

E:

Routed FortiLink support, addressing and authorization jointly enable adoption. The FortiGate must authorize the discovered or added switch before centrally pushing its managed configuration.

Incorrect Answers

C:

When traffic traverses firewalls, approved policies must permit the required management sessions. Here it is a different control and will not directly use correct L3 topology, configure IP and approve the switch.

D:

Network-layer routes must carry traffic between the required FortiGate and FortiSwitch control endpoints. This is not sufficient to use correct L3 topology, configure IP and approve the switch.

F:

A direct bridged FortiLink path does not by itself address management through intermediate IP routers. For this scenario it cannot by itself use correct L3 topology, configure IP and approve the switch.

Fortinet NSE 5 - FortiSwitch 7.6 Administrator (NSE5_FSW_AD-7.6) Practice Tests

UP

SPECIAL OFFER: GET 10% OFF

This is ONE TIME OFFER

ExamSnap Discount Offer
Enter Your Email Address to Receive Your 10% Off Discount Code

A confirmation link will be sent to this email address to verify your login. *We value your privacy. We will not rent or sell your email address.

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.