ISA IC33 ISA-IEC 62443 Cybersecurity Risk Assessment Specialist Exam Dumps, Practice Test Questions

100% Latest & Updated ISA IC33 ISA-IEC 62443 Cybersecurity Risk Assessment Specialist Practice Test Questions, Exam Dumps & Verified Answers!
30 Days Free Updates, Instant Download!

ISA IC33 ISA-IEC 62443 Cybersecurity Risk Assessment Specialist  Premium File
$76.99
$69.99

IC33 ISA-IEC 62443 Cybersecurity Risk Assessment Specialist Premium File

  • Premium File: 90 Questions & Answers. Last update: Nov 18, 2026
  • Latest Questions
  • 100% Accurate Answers
  • Fast Exam Updates

IC33 ISA-IEC 62443 Cybersecurity Risk Assessment Specialist Premium File

ISA IC33 ISA-IEC 62443 Cybersecurity Risk Assessment Specialist  Premium File
  • Premium File: 90 Questions & Answers. Last update: Nov 18, 2026
  • Latest Questions
  • 100% Accurate Answers
  • Fast Exam Updates
$76.99
$69.99

ISA IC33 ISA-IEC 62443 Cybersecurity Risk Assessment Specialist Practice Test 26

Question 250

Choose THREE elements of an evidence-based response plan for "Mining site third-party tunnel shutdown": direct correction, a focused verification and an appropriate operating or evidence boundary. The original facts are: An approved maintenance test finds an unexpected persistent vendor tunnel, and the tester wants to disconnect it immediately without knowing the control-system dependency.

  1. Supplement wired capture with authorized radio gateway logs and sensor inventory records.
  2. Walk through a controlled dependency check that identifies whether disconnecting the path affects monitoring or support.
  3. Defer active checks to standby or an offline replica and use passive evidence during heating.
  4. Document the tunnel and escalate to operations and the risk owner for a safety-informed containment decision.
  5. Quantify packet loss and repeat passive collection with adequate capture capacity or narrower filters.
  6. Avoid making network changes outside assessment authority.

Explanation

Correct Answers

B:

Walk through a controlled dependency check that identifies whether disconnecting the path affects monitoring or support. This is one element of the case-specific plan for mining site third-party tunnel shutdown. The source scenario is: An approved maintenance test finds an unexpected persistent vendor tunnel, and the tester wants to disconnect it immediately without knowing the control-system dependency. The central corrective action is: Document the tunnel and escalate to operations and the risk owner for a safety-informed containment decision.

D:

Document the tunnel and escalate to operations and the risk owner for a safety-informed containment decision. This is one element of the case-specific plan for mining site third-party tunnel shutdown. The source scenario is: An approved maintenance test finds an unexpected persistent vendor tunnel, and the tester wants to disconnect it immediately without knowing the control-system dependency. The central corrective action is: Document the tunnel and escalate to operations and the risk owner for a safety-informed containment decision.

F:

Avoid making network changes outside assessment authority. This is one element of the case-specific plan for mining site third-party tunnel shutdown. The source scenario is: An approved maintenance test finds an unexpected persistent vendor tunnel, and the tester wants to disconnect it immediately without knowing the control-system dependency. The central corrective action is: Document the tunnel and escalate to operations and the risk owner for a safety-informed containment decision.

Incorrect Answers

A:

Supplement wired capture with authorized radio gateway logs and sensor inventory records. That component supports a separate case: A risk review uses only a wired packet capture and claims all reservoir level sensors are accounted for, though several report via low-power radio. The present plan requires document the tunnel and escalate to operations and the risk owner for a safety-informed containment decision Its verification is: Walk through a controlled dependency check that identifies whether disconnecting the path affects monitoring or support.

C:

Defer active checks to standby or an offline replica and use passive evidence during heating. That component supports a separate case: A glass-furnace controller accepts network queries safely only in standby, but the team has scheduled a vulnerability agent during heating. The present plan requires document the tunnel and escalate to operations and the risk owner for a safety-informed containment decision Its verification is: Walk through a controlled dependency check that identifies whether disconnecting the path affects monitoring or support.

E:

Quantify packet loss and repeat passive collection with adequate capture capacity or narrower filters. That component supports a separate case: A roadside controller monitoring session drops bursts of packets during morning traffic, but the analyst reports no control command anomalies. The present plan requires document the tunnel and escalate to operations and the risk owner for a safety-informed containment decision Its verification is: Walk through a controlled dependency check that identifies whether disconnecting the path affects monitoring or support.

Question 251

At the fictional industrial site, the "Water reservoir wireless sensor evidence" assessment records: A risk review uses only a wired packet capture and claims all reservoir level sensors are accounted for, though several report via low-power radio. Which single diagnosis is MOST directly supported by this evidence?

  1. Extrapolating one role's test to all privileged identities leaves unassessed access paths.
  2. The evidence collection method omits a distinct wireless telemetry channel.
  3. The assessment method conflicts with the manufacturer's supported operating-state constraint.
  4. The intended target cannot be uniquely identified from available topology evidence.

Explanation

Correct Answer

B:

The evidence collection method omits a distinct wireless telemetry channel. In the Water reservoir wireless sensor evidence case, the reported evidence is: A risk review uses only a wired packet capture and claims all reservoir level sensors are accounted for, though several report via low-power radio.

Incorrect Answers

A:

Extrapolating one role's test to all privileged identities leaves unassessed access paths. That is associated with a different source scenario: A baking line reviewer tests the shared operator role but infers that every maintenance account has the same permissions. The distinguishing evidence here is: A risk review uses only a wired packet capture and claims all reservoir level sensors are accounted for, though several report via low-power radio.

C:

The assessment method conflicts with the manufacturer's supported operating-state constraint. That is associated with a different source scenario: A glass-furnace controller accepts network queries safely only in standby, but the team has scheduled a vulnerability agent during heating. The distinguishing evidence here is: A risk review uses only a wired packet capture and claims all reservoir level sensors are accounted for, though several report via low-power radio.

D:

The intended target cannot be uniquely identified from available topology evidence. That is associated with a different source scenario: A maintenance switch has several ports, and the assessment team cannot determine which port leads to the cement kiln PLC without interrupting operations. The distinguishing evidence here is: A risk review uses only a wired packet capture and claims all reservoir level sensors are accounted for, though several report via low-power radio.

Question 252

The assessment team has verified this issue in the "Water reservoir wireless sensor evidence" case: The evidence collection method omits a distinct wireless telemetry channel. Given the observed facts — A risk review uses only a wired packet capture and claims all reservoir level sensors are accounted for, though several report via low-power radio. — which specific next action BEST addresses the actual assessment gap?

  1. Supplement wired capture with authorized radio gateway logs and sensor inventory records.
  2. Coordinate approved notice windows, source identities and incident contacts with operations before the check.
  3. Use switch configuration and labeled-cable records to map the path before any active testing.
  4. Defer active checks to standby or an offline replica and use passive evidence during heating.

Explanation

Correct Answer

A:

Supplement wired capture with authorized radio gateway logs and sensor inventory records. The case requires a response to this observed condition: A risk review uses only a wired packet capture and claims all reservoir level sensors are accounted for, though several report via low-power radio. A relevant result to check is: Reconcile sample sensor IDs and timestamps across radio and wired gateways to confirm end-to-end coverage.

Incorrect Answers

B:

Coordinate approved notice windows, source identities and incident contacts with operations before the check. The source catalog associates that remedy with a different case: A metro ventilation operations team receives no notice of an approved sensor check and interprets its harmless query traffic as an attack. For the current case, the bounded change is: Supplement wired capture with authorized radio gateway logs and sensor inventory records.

C:

Use switch configuration and labeled-cable records to map the path before any active testing. The source catalog associates that remedy with a different case: A maintenance switch has several ports, and the assessment team cannot determine which port leads to the cement kiln PLC without interrupting operations. For the current case, the bounded change is: Supplement wired capture with authorized radio gateway logs and sensor inventory records.

D:

Defer active checks to standby or an offline replica and use passive evidence during heating. The source catalog associates that remedy with a different case: A glass-furnace controller accepts network queries safely only in standby, but the team has scheduled a vulnerability agent during heating. For the current case, the bounded change is: Supplement wired capture with authorized radio gateway logs and sensor inventory records.

Question 253

After proposing this correction to "Water reservoir wireless sensor evidence": Supplement wired capture with authorized radio gateway logs and sensor inventory records. Which focused validation would BEST demonstrate the intended result without an unsupported success claim?

  1. Run a notification rehearsal and confirm the SOC and control-room staff identify the traffic as authorized.
  2. Verify the assessment account cannot reach an unrelated controller while the approved read-only checks still work.
  3. Walk through a controlled dependency check that identifies whether disconnecting the path affects monitoring or support.
  4. Reconcile sample sensor IDs and timestamps across radio and wired gateways to confirm end-to-end coverage.

Explanation

Correct Answer

D:

Reconcile sample sensor IDs and timestamps across radio and wired gateways to confirm end-to-end coverage. This is the case-specific verification, not a generic product or process check. The observed problem is: A risk review uses only a wired packet capture and claims all reservoir level sensors are accounted for, though several report via low-power radio.

Incorrect Answers

A:

Run a notification rehearsal and confirm the SOC and control-room staff identify the traffic as authorized. This investigates a different condition, such as: A metro ventilation operations team receives no notice of an approved sensor check and interprets its harmless query traffic as an attack. The reported condition in this case is: A risk review uses only a wired packet capture and claims all reservoir level sensors are accounted for, though several report via low-power radio.

B:

Verify the assessment account cannot reach an unrelated controller while the approved read-only checks still work. This investigates a different condition, such as: A third-party assessor requests the plant-wide administrator password to assess a single conveyor HMI. The reported condition in this case is: A risk review uses only a wired packet capture and claims all reservoir level sensors are accounted for, though several report via low-power radio.

C:

Walk through a controlled dependency check that identifies whether disconnecting the path affects monitoring or support. This investigates a different condition, such as: An approved maintenance test finds an unexpected persistent vendor tunnel, and the tester wants to disconnect it immediately without knowing the control-system dependency. The reported condition in this case is: A risk review uses only a wired packet capture and claims all reservoir level sensors are accounted for, though several report via low-power radio.

Question 254

For the "Water reservoir wireless sensor evidence" scenario, the team must preserve defensible assessment or operating controls while addressing: A risk review uses only a wired packet capture and claims all reservoir level sensors are accounted for, though several report via low-power radio. Which additional safeguard is MOST appropriate?

  1. Record tool versions and approvals in the assessment plan.
  2. Document gateway failures as possible data-availability risks.
  3. Retain the original permit and document any changed scope explicitly.
  4. Keep the change log linked to each affected finding.

Explanation

Correct Answer

B:

Document gateway failures as possible data-availability risks. It protects the scope and evidence for the proposed response: Supplement wired capture with authorized radio gateway logs and sensor inventory records. The original case adds this limit: Use passive collection that does not disrupt licensed radio links.

Incorrect Answers

A:

Record tool versions and approvals in the assessment plan. It concerns a different source case: A rail-yard risk team downloads a vulnerability scanner plugin from a community mirror without checking provenance or integrity. The relevant boundary here is: Use passive collection that does not disrupt licensed radio links.

C:

Retain the original permit and document any changed scope explicitly. It concerns a different source case: A penetration test is approved for a relay lab, but the operations shift schedules live switching during the same hour and requests a quick scope extension. The relevant boundary here is: Use passive collection that does not disrupt licensed radio links.

D:

Keep the change log linked to each affected finding. It concerns a different source case: The assessment starts on PLC firmware 5.1; maintenance updates half the line to 5.2 before the final report, invalidating some applicability claims. The relevant boundary here is: Use passive collection that does not disrupt licensed radio links.

Question 255

Choose TWO mutually reinforcing parts of a controlled assessment response to "Water reservoir wireless sensor evidence": one addresses the specific finding and another protects an essential evidence, safety or authorization boundary. The verified issue is: The evidence collection method omits a distinct wireless telemetry channel.

  1. Use passive collection that does not disrupt licensed radio links.
  2. Supplement wired capture with authorized radio gateway logs and sensor inventory records.
  3. Use switch configuration and labeled-cable records to map the path before any active testing.
  4. Defer active checks to standby or an offline replica and use passive evidence during heating.
  5. Coordinate approved notice windows, source identities and incident contacts with operations before the check.

Explanation

Correct Answers

A:

Use passive collection that does not disrupt licensed radio links. This is one element of the case-specific plan for water reservoir wireless sensor evidence. The source scenario is: A risk review uses only a wired packet capture and claims all reservoir level sensors are accounted for, though several report via low-power radio. The central corrective action is: Supplement wired capture with authorized radio gateway logs and sensor inventory records.

B:

Supplement wired capture with authorized radio gateway logs and sensor inventory records. This is one element of the case-specific plan for water reservoir wireless sensor evidence. The source scenario is: A risk review uses only a wired packet capture and claims all reservoir level sensors are accounted for, though several report via low-power radio. The central corrective action is: Supplement wired capture with authorized radio gateway logs and sensor inventory records.

Incorrect Answers

C:

Use switch configuration and labeled-cable records to map the path before any active testing. That component supports a separate case: A maintenance switch has several ports, and the assessment team cannot determine which port leads to the cement kiln PLC without interrupting operations. The present plan requires supplement wired capture with authorized radio gateway logs and sensor inventory records Its verification is: Reconcile sample sensor IDs and timestamps across radio and wired gateways to confirm end-to-end coverage.

D:

Defer active checks to standby or an offline replica and use passive evidence during heating. That component supports a separate case: A glass-furnace controller accepts network queries safely only in standby, but the team has scheduled a vulnerability agent during heating. The present plan requires supplement wired capture with authorized radio gateway logs and sensor inventory records Its verification is: Reconcile sample sensor IDs and timestamps across radio and wired gateways to confirm end-to-end coverage.

E:

Coordinate approved notice windows, source identities and incident contacts with operations before the check. That component supports a separate case: A metro ventilation operations team receives no notice of an approved sensor check and interprets its harmless query traffic as an attack. The present plan requires supplement wired capture with authorized radio gateway logs and sensor inventory records Its verification is: Reconcile sample sensor IDs and timestamps across radio and wired gateways to confirm end-to-end coverage.

Question 256

At the fictional industrial site, the "Refinery initial consequence screen" assessment records: A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable. Which single diagnosis is MOST directly supported by this evidence?

  1. The screening method excludes process consequences and can misprioritize high-impact assets.
  2. Replacement cost is not a meaningful proxy for the controller's safety-related mission impact.
  3. An external operating dependency with control authority is missing from the initial system boundary.
  4. The conduit's documented purpose underrepresents its actual command privileges.

Explanation

Correct Answer

A:

The screening method excludes process consequences and can misprioritize high-impact assets. In the Refinery initial consequence screen case, the reported evidence is: A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable.

Incorrect Answers

B:

Replacement cost is not a meaningful proxy for the controller's safety-related mission impact. That is associated with a different source scenario: An airport assesses a small ventilation controller as low criticality by asset value, but it serves the emergency smoke-extraction route. The distinguishing evidence here is: A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable.

C:

An external operating dependency with control authority is missing from the initial system boundary. That is associated with a different source scenario: A microgrid operator excludes an upstream dispatch platform from the system under consideration, although it can change power setpoints. The distinguishing evidence here is: A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable.

D:

The conduit's documented purpose underrepresents its actual command privileges. That is associated with a different source scenario: A cement kiln's remote diagnostics path is labeled monitor-only in the zone diagram, but the same VPN allows configuration writes. The distinguishing evidence here is: A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable.

Question 257

The assessment team has verified this issue in the "Refinery initial consequence screen" case: The screening method excludes process consequences and can misprioritize high-impact assets. Given the observed facts — A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable. — which specific next action BEST addresses the actual assessment gap?

  1. Expand high-level risk scenarios to include field access and temporary connections.
  2. Add a site-specific consequence scale with safety, environmental and production effects before the initial ranking.
  3. Model the jump host as a conduit endpoint with separate tenant privileges and accountability.
  4. Define risk ownership and approval levels, then route tolerable-risk decisions through authorized management.

Explanation

Correct Answer

B:

Add a site-specific consequence scale with safety, environmental and production effects before the initial ranking. The case requires a response to this observed condition: A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable. A relevant result to check is: Score a known loss-of-cooling scenario and confirm consequence changes the result despite limited internet exposure.

Incorrect Answers

A:

Expand high-level risk scenarios to include field access and temporary connections. The source catalog associates that remedy with a different case: A rail organization considers a trackside cabinet low risk because it has no internet link, despite public physical access and a maintenance port. For the current case, the bounded change is: Add a site-specific consequence scale with safety, environmental and production effects before the initial ranking.

C:

Model the jump host as a conduit endpoint with separate tenant privileges and accountability. The source catalog associates that remedy with a different case: The baggage handling system has one contractor for motor controls and another for belt monitoring; both use a shared jump host with no zone-boundary documentation. For the current case, the bounded change is: Add a site-specific consequence scale with safety, environmental and production effects before the initial ranking.

D:

Define risk ownership and approval levels, then route tolerable-risk decisions through authorized management. The source catalog associates that remedy with a different case: The pipeline cyber team identifies a high residual risk but closes it as accepted because an analyst signed the worksheet without a named business risk owner. For the current case, the bounded change is: Add a site-specific consequence scale with safety, environmental and production effects before the initial ranking.

Question 258

After proposing this correction to "Refinery initial consequence screen": Add a site-specific consequence scale with safety, environmental and production effects before the initial ranking. Which focused validation would BEST demonstrate the intended result without an unsupported success claim?

  1. Trace the tension-control hazard from PHA to the cyber risk register and confirm the associated severity is retained.
  2. Review every listed external system and require an evidenced pathway to the operational function.
  3. Score a known loss-of-cooling scenario and confirm consequence changes the result despite limited internet exposure.
  4. Verify the zone drawing separates safety controls and guest devices while preserving necessary traffic descriptions.

Explanation

Correct Answer

C:

Score a known loss-of-cooling scenario and confirm consequence changes the result despite limited internet exposure. This is the case-specific verification, not a generic product or process check. The observed problem is: A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable.

Incorrect Answers

A:

Trace the tension-control hazard from PHA to the cyber risk register and confirm the associated severity is retained. This investigates a different condition, such as: A textile site has a process hazard assessment showing loss of tension control can cause severe machinery damage, yet the cyber assessment evaluates only downtime cost. The reported condition in this case is: A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable.

B:

Review every listed external system and require an evidenced pathway to the operational function. This investigates a different condition, such as: A depot's initial risk assessment expands from an electric-bus charger network to all corporate email systems without showing a relationship to charging operations. The reported condition in this case is: A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable.

D:

Verify the zone drawing separates safety controls and guest devices while preserving necessary traffic descriptions. This investigates a different condition, such as: An energy plant places boiler protection controllers and visitor Wi-Fi devices in the same proposed security zone because they share one physical switch. The reported condition in this case is: A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable.

Question 259

For the "Refinery initial consequence screen" scenario, the team must preserve defensible assessment or operating controls while addressing: A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable. Which additional safeguard is MOST appropriate?

  1. Keep inherent impact distinct from current network reachability.
  2. Require authorized approval for a newly evaluated residual risk.
  3. Preserve source and destination ownership for dispatch messages.
  4. Do not allow an unverified external feed to override safety limits.

Explanation

Correct Answer

A:

Keep inherent impact distinct from current network reachability. It protects the scope and evidence for the proposed response: Add a site-specific consequence scale with safety, environmental and production effects before the initial ranking. The original case adds this limit: Have process engineers validate physical outcomes.

Incorrect Answers

B:

Require authorized approval for a newly evaluated residual risk. It concerns a different source case: A hydro operator retains a five-year-old accepted risk rating after installing new remote control capabilities and increasing generation output. The relevant boundary here is: Have process engineers validate physical outcomes.

C:

Preserve source and destination ownership for dispatch messages. It concerns a different source case: A microgrid operator excludes an upstream dispatch platform from the system under consideration, although it can change power setpoints. The relevant boundary here is: Have process engineers validate physical outcomes.

D:

Do not allow an unverified external feed to override safety limits. It concerns a different source case: A heating network receives weather data from an external API, but the assessment lists the service as fully trusted and excludes corrupted measurements from risk scenarios. The relevant boundary here is: Have process engineers validate physical outcomes.

Question 260

Choose THREE elements of an evidence-based response plan for "Refinery initial consequence screen": direct correction, a focused verification and an appropriate operating or evidence boundary. The original facts are: A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable.

  1. Score a known loss-of-cooling scenario and confirm consequence changes the result despite limited internet exposure.
  2. Define risk ownership and approval levels, then route tolerable-risk decisions through authorized management.
  3. Add a site-specific consequence scale with safety, environmental and production effects before the initial ranking.
  4. Expand high-level risk scenarios to include field access and temporary connections.
  5. Have process engineers validate physical outcomes.
  6. Model the jump host as a conduit endpoint with separate tenant privileges and accountability.

Explanation

Correct Answers

A:

Score a known loss-of-cooling scenario and confirm consequence changes the result despite limited internet exposure. This is one element of the case-specific plan for refinery initial consequence screen. The source scenario is: A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable. The central corrective action is: Add a site-specific consequence scale with safety, environmental and production effects before the initial ranking.

C:

Add a site-specific consequence scale with safety, environmental and production effects before the initial ranking. This is one element of the case-specific plan for refinery initial consequence screen. The source scenario is: A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable. The central corrective action is: Add a site-specific consequence scale with safety, environmental and production effects before the initial ranking.

E:

Have process engineers validate physical outcomes. This is one element of the case-specific plan for refinery initial consequence screen. The source scenario is: A refinery's initial cyber risk review ranks all control nodes equally because its template asks only whether each device is internet reachable. The central corrective action is: Add a site-specific consequence scale with safety, environmental and production effects before the initial ranking.

Incorrect Answers

B:

Define risk ownership and approval levels, then route tolerable-risk decisions through authorized management. That component supports a separate case: The pipeline cyber team identifies a high residual risk but closes it as accepted because an analyst signed the worksheet without a named business risk owner. The present plan requires add a site-specific consequence scale with safety, environmental and production effects before the initial ranking Its verification is: Score a known loss-of-cooling scenario and confirm consequence changes the result despite limited internet exposure.

D:

Expand high-level risk scenarios to include field access and temporary connections. That component supports a separate case: A rail organization considers a trackside cabinet low risk because it has no internet link, despite public physical access and a maintenance port. The present plan requires add a site-specific consequence scale with safety, environmental and production effects before the initial ranking Its verification is: Score a known loss-of-cooling scenario and confirm consequence changes the result despite limited internet exposure.

F:

Model the jump host as a conduit endpoint with separate tenant privileges and accountability. That component supports a separate case: The baggage handling system has one contractor for motor controls and another for belt monitoring; both use a shared jump host with no zone-boundary documentation. The present plan requires add a site-specific consequence scale with safety, environmental and production effects before the initial ranking Its verification is: Score a known loss-of-cooling scenario and confirm consequence changes the result despite limited internet exposure.

IC33 ISA-IEC 62443 Cybersecurity Risk Assessment Specialist Practice Tests

UP

SPECIAL OFFER: GET 10% OFF

This is ONE TIME OFFER

ExamSnap Discount Offer
Enter Your Email Address to Receive Your 10% Off Discount Code

A confirmation link will be sent to this email address to verify your login. *We value your privacy. We will not rent or sell your email address.

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.