Juniper JN0-336 Exam Dumps, Practice Test Questions

100% Latest & Updated Juniper JN0-336 Practice Test Questions, Exam Dumps & Verified Answers!
30 Days Free Updates, Instant Download!

Juniper JN0-336  Premium File
$54.99
$49.99

JN0-336 Premium File

  • Premium File: 98 Questions & Answers. Last update: Nov 12, 2026
  • Latest Questions
  • 100% Accurate Answers
  • Fast Exam Updates

JN0-336 Premium File

Juniper JN0-336  Premium File
  • Premium File: 98 Questions & Answers. Last update: Nov 12, 2026
  • Latest Questions
  • 100% Accurate Answers
  • Fast Exam Updates
$54.99
$49.99

Juniper JN0-336 Practice Test 44

Question 430

A security team quarantines every camera because one camera model emitted unusual DNS behavior during a firmware update. Which accountable function should approve the decision and residual risk?

  1. The physical security owner approves narrow IoT remediation.
  2. The identity change owner approves proportional cache recovery.
  3. The resilience engineering owner accepts single-link degradation handling.
  4. The intercompany change board approves the staged VPN rollout.

Explanation

Correct Answer

A:

The physical security owner approves narrow IoT remediation. This places acceptance of the iot profiling and containment change with its accountable owner rather than an unrelated service team. The reported condition is a security team quarantines every camera because one camera model emitted unusual DNS behavior during a firmware update.

Incorrect Answers

B:

The identity change owner approves proportional cache recovery. That function does not own this iot profiling and containment decision; accountable approval belongs to The physical security owner approves narrow IoT remediation.

C:

The resilience engineering owner accepts single-link degradation handling. That function does not own this iot profiling and containment decision; accountable approval belongs to The physical security owner approves narrow IoT remediation.

D:

The intercompany change board approves the staged VPN rollout. That function does not own this iot profiling and containment decision; accountable approval belongs to The physical security owner approves narrow IoT remediation.

Question 431

An IoT device profile remains bound to a MAC address after network hardware replacement and its new interface cannot reach controllers. Which underlying security or operational dependency BEST explains the situation?

  1. Unreviewed encrypted-traffic reputation signals may cause false positives for legitimate shared IP infrastructure.
  2. Unverified or stale threat intelligence entries can cause false-positive blocks when feed scope is too broad.
  3. Identity or profiling associations tied to old device attributes may not follow legitimate hardware replacements.
  4. A lower score alone cannot establish that required endpoint incident checks and persistence removal are complete.

Explanation

Correct Answer

C:

Identity or profiling associations tied to old device attributes may not follow legitimate hardware replacements. This accounts for the reported condition: an IoT device profile remains bound to a MAC address after network hardware replacement and its new interface cannot reach controllers.

Incorrect Answers

A:

Unreviewed encrypted-traffic reputation signals may cause false positives for legitimate shared IP infrastructure. But identity or profiling associations tied to old device attributes may not follow legitimate hardware replacements.

B:

Unverified or stale threat intelligence entries can cause false-positive blocks when feed scope is too broad. But identity or profiling associations tied to old device attributes may not follow legitimate hardware replacements.

D:

A lower score alone cannot establish that required endpoint incident checks and persistence removal are complete. But identity or profiling associations tied to old device attributes may not follow legitimate hardware replacements.

Question 432

An IoT device profile remains bound to a MAC address after network hardware replacement and its new interface cannot reach controllers. Which investigation should be completed before changing the SRX configuration?

  1. Review eligible file extensions, matched policies, TLS visibility and actual submission counters.
  2. Compare the new hardware identity, inventory approval, policy mapping and observed blocked sessions.
  3. Compare signature package version, license entitlements, update job history and download errors.
  4. Inspect feed fetch errors, server certificate chain, last successful refresh and indicator age.

Explanation

Correct Answer

B:

Compare the new hardware identity, inventory approval, policy mapping and observed blocked sessions. These checks distinguish the actual iot profiling and containment state before a configuration change; identity or profiling associations tied to old device attributes may not follow legitimate hardware replacements. The reported condition is an IoT device profile remains bound to a MAC address after network hardware replacement and its new interface cannot reach controllers.

Incorrect Answers

A:

Review eligible file extensions, matched policies, TLS visibility and actual submission counters. For the observed problem, compare the new hardware identity, inventory approval, policy mapping and observed blocked sessions.

C:

Compare signature package version, license entitlements, update job history and download errors. For the observed problem, compare the new hardware identity, inventory approval, policy mapping and observed blocked sessions.

D:

Inspect feed fetch errors, server certificate chain, last successful refresh and indicator age. For the observed problem, compare the new hardware identity, inventory approval, policy mapping and observed blocked sessions.

Question 433

An IoT device profile remains bound to a MAC address after network hardware replacement and its new interface cannot reach controllers. Which change most directly addresses the identified cause without creating unrelated access?

  1. Activate the approved C2 prevention policy for the intended egress zones and update the feed.
  2. Update the authenticated device identity mapping and retain its minimal telemetry policy.
  3. Add the supported document type to the appropriate approved inspection profile and confirm transport eligibility.
  4. Restore protected feed synchronization and alert on update failures instead of claiming complete coverage.

Explanation

Correct Answer

B:

Update the authenticated device identity mapping and retain its minimal telemetry policy. The change addresses the underlying condition: identity or profiling associations tied to old device attributes may not follow legitimate hardware replacements. The reported condition is an IoT device profile remains bound to a MAC address after network hardware replacement and its new interface cannot reach controllers.

Incorrect Answers

A:

Activate the approved C2 prevention policy for the intended egress zones and update the feed. That change does not correct the established failure and could modify unrelated controls. This case requires Update the authenticated device identity mapping and retain its minimal telemetry policy.

C:

Add the supported document type to the appropriate approved inspection profile and confirm transport eligibility. That change does not correct the established failure and could modify unrelated controls. This case requires Update the authenticated device identity mapping and retain its minimal telemetry policy.

D:

Restore protected feed synchronization and alert on update failures instead of claiming complete coverage. That change does not correct the established failure and could modify unrelated controls. This case requires Update the authenticated device identity mapping and retain its minimal telemetry policy.

Question 434

An IoT device profile remains bound to a MAC address after network hardware replacement and its new interface cannot reach controllers. Which post-change result would provide the strongest direct evidence of success?

  1. Cloud status returns online and normal file analysis events resume for the branch.
  2. The compromised test host is contained and unaffected peers keep their approved connections.
  3. Synthetic high-risk DNS patterns trigger the designed prevention while normal resolver use continues.
  4. The replacement device connects only to its assigned controllers under the existing least-privilege scope.

Explanation

Correct Answer

D:

The replacement device connects only to its assigned controllers under the existing least-privilege scope. A complete test must demonstrate the intended result, not just show that a setting was saved. The reported condition is an IoT device profile remains bound to a MAC address after network hardware replacement and its new interface cannot reach controllers.

Incorrect Answers

A:

Cloud status returns online and normal file analysis events resume for the branch. It does not demonstrate that the reported problem has been resolved; the replacement device connects only to its assigned controllers under the existing least-privilege scope.

B:

The compromised test host is contained and unaffected peers keep their approved connections. It does not demonstrate that the reported problem has been resolved; the replacement device connects only to its assigned controllers under the existing least-privilege scope.

C:

Synthetic high-risk DNS patterns trigger the designed prevention while normal resolver use continues. It does not demonstrate that the reported problem has been resolved; the replacement device connects only to its assigned controllers under the existing least-privilege scope.

Question 435

An IoT device profile remains bound to a MAC address after network hardware replacement and its new interface cannot reach controllers. Select THREE elements that together test the cause, implement the appropriate correction, and verify the resulting flow.

  1. Restore the supported verdict lookup behavior with validated expiration and trust controls.
  2. Compare the new hardware identity, inventory approval, policy mapping and observed blocked sessions.
  3. Compare ETI threat summary, ports, timing and independent partner traffic/business confirmation.
  4. The replacement device connects only to its assigned controllers under the existing least-privilege scope.
  5. Update the authenticated device identity mapping and retain its minimal telemetry policy.
  6. A known bad sample at that domain triggers blocking and approved business destinations remain accessible.

Explanation

Correct Answers

B:

Compare the new hardware identity, inventory approval, policy mapping and observed blocked sessions. These checks distinguish the actual iot profiling and containment state before a configuration change; identity or profiling associations tied to old device attributes may not follow legitimate hardware replacements. The decision also depends on the replacement device connects only to its assigned controllers under the existing least-privilege scope.

D:

The replacement device connects only to its assigned controllers under the existing least-privilege scope. A complete test must demonstrate the intended result, not just show that a setting was saved. The decision also depends on compare the new hardware identity, inventory approval, policy mapping and observed blocked sessions.

E:

Update the authenticated device identity mapping and retain its minimal telemetry policy. The change addresses the underlying condition: identity or profiling associations tied to old device attributes may not follow legitimate hardware replacements. The decision also depends on compare the new hardware identity, inventory approval, policy mapping and observed blocked sessions.

Incorrect Answers

A:

Restore the supported verdict lookup behavior with validated expiration and trust controls. That change does not correct the established failure and could modify unrelated controls. This case requires Update the authenticated device identity mapping and retain its minimal telemetry policy.

C:

Compare ETI threat summary, ports, timing and independent partner traffic/business confirmation. For the observed problem, compare the new hardware identity, inventory approval, policy mapping and observed blocked sessions.

F:

A known bad sample at that domain triggers blocking and approved business destinations remain accessible. It does not demonstrate that the reported problem has been resolved; the replacement device connects only to its assigned controllers under the existing least-privilege scope.

Question 436

An industrial gateway stops reporting telemetry because a new threat policy blocks a legitimate proprietary protocol it misclassifies. Which underlying security or operational dependency BEST explains the situation?

  1. A false-positive classification can block supported industrial control traffic when protocol fingerprints are poorly tuned.
  2. A missing signature-update entitlement can leave the predefined attack database stale despite local IDP capability.
  3. Expired or unreachable DNS threat feed updates can degrade newly emerging domain detection coverage.
  4. An oversized feed prefix can block thousands of unrelated addresses beyond the validated indicator.

Explanation

Correct Answer

A:

A false-positive classification can block supported industrial control traffic when protocol fingerprints are poorly tuned. This accounts for the reported condition: an industrial gateway stops reporting telemetry because a new threat policy blocks a legitimate proprietary protocol it misclassifies.

Incorrect Answers

B:

A missing signature-update entitlement can leave the predefined attack database stale despite local IDP capability. But a false-positive classification can block supported industrial control traffic when protocol fingerprints are poorly tuned.

C:

Expired or unreachable DNS threat feed updates can degrade newly emerging domain detection coverage. But a false-positive classification can block supported industrial control traffic when protocol fingerprints are poorly tuned.

D:

An oversized feed prefix can block thousands of unrelated addresses beyond the validated indicator. But a false-positive classification can block supported industrial control traffic when protocol fingerprints are poorly tuned.

Question 437

An industrial gateway stops reporting telemetry because a new threat policy blocks a legitimate proprietary protocol it misclassifies. Which investigation should be completed before changing the SRX configuration?

  1. Inspect flow samples, IoT threat verdict, permitted endpoints and exact rule match.
  2. Test the cloud endpoint path, configured proxy trust and ATP service connection from the affected SRX.
  3. Review indicator confidence, observed false positives and intended protected zones before applying enforcement.
  4. Inventory allowlist provenance, last review dates and current threat findings for each exemption.

Explanation

Correct Answer

A:

Before making changes, Inspect flow samples, IoT threat verdict, permitted endpoints and exact rule match. This evidence distinguishes the stated cause from adjacent security-zone, route, service, or logging hypotheses.

Incorrect Answers

B:

Test the cloud endpoint path, configured proxy trust and ATP service connection from the affected SRX. For the observed problem, inspect flow samples, IoT threat verdict, permitted endpoints and exact rule match.

C:

Review indicator confidence, observed false positives and intended protected zones before applying enforcement. For the observed problem, inspect flow samples, IoT threat verdict, permitted endpoints and exact rule match.

D:

Inventory allowlist provenance, last review dates and current threat findings for each exemption. For the observed problem, inspect flow samples, IoT threat verdict, permitted endpoints and exact rule match.

Question 438

An industrial gateway stops reporting telemetry because a new threat policy blocks a legitimate proprietary protocol it misclassifies. Which change most directly addresses the identified cause without creating unrelated access?

  1. Restore the supported verdict lookup behavior with validated expiration and trust controls.
  2. Refine the classification or service-specific exception in a tightly tested OT maintenance window.
  3. Move or re-enroll the SRX through the authorized workflow into the correct policy realm.
  4. Apply the narrowly scoped approved containment action to the listed host without blocking the entire subnet.

Explanation

Correct Answer

B:

Refine the classification or service-specific exception in a tightly tested OT maintenance window. The change addresses the underlying condition: a false-positive classification can block supported industrial control traffic when protocol fingerprints are poorly tuned.

Incorrect Answers

A:

Restore the supported verdict lookup behavior with validated expiration and trust controls. That change does not correct the established failure and could modify unrelated controls. This case requires Refine the classification or service-specific exception in a tightly tested OT maintenance window.

C:

Move or re-enroll the SRX through the authorized workflow into the correct policy realm. That change does not correct the established failure and could modify unrelated controls. This case requires Refine the classification or service-specific exception in a tightly tested OT maintenance window.

D:

Apply the narrowly scoped approved containment action to the listed host without blocking the entire subnet. That change does not correct the established failure and could modify unrelated controls. This case requires Refine the classification or service-specific exception in a tightly tested OT maintenance window.

Question 439

An industrial gateway stops reporting telemetry because a new threat policy blocks a legitimate proprietary protocol it misclassifies. Select TWO complementary requirements: one tests the actual correction and one identifies its accountable approval.

  1. Cloud status returns online and normal file analysis events resume for the branch.
  2. The plant control security owner signs off on the safety-aware exception.
  3. The identified host is contained and unrelated operational systems maintain approved service.
  4. The stateful firewall availability owner approves fabric reliability repair.
  5. Industrial telemetry resumes and validated hostile IoT patterns remain blocked.

Explanation

Correct Answers

B:

The plant control security owner signs off on the safety-aware exception. This places acceptance of the iot profiling and containment change with its accountable owner rather than an unrelated service team. The decision also depends on industrial telemetry resumes and validated hostile IoT patterns remain blocked.

E:

Industrial telemetry resumes and validated hostile IoT patterns remain blocked. A complete test must demonstrate the intended result, not just show that a setting was saved.

Incorrect Answers

A:

Cloud status returns online and normal file analysis events resume for the branch. It does not demonstrate that the reported problem has been resolved; industrial telemetry resumes and validated hostile IoT patterns remain blocked.

C:

The identified host is contained and unrelated operational systems maintain approved service. It does not demonstrate that the reported problem has been resolved; industrial telemetry resumes and validated hostile IoT patterns remain blocked.

D:

The stateful firewall availability owner approves fabric reliability repair. That function does not own this iot profiling and containment decision; accountable approval belongs to The plant control security owner signs off on the safety-aware exception.

Question 440

An industrial gateway stops reporting telemetry because a new threat policy blocks a legitimate proprietary protocol it misclassifies. Which accountable function should approve the decision and residual risk?

  1. The management compatibility owner approves supported release pairing.
  2. The plant control security owner signs off on the safety-aware exception.
  3. The operations observability owner approves VPN probe target maintenance.
  4. The VPN address-plan owner approves nonoverlapping selectors.

Explanation

Correct Answer

B:

The plant control security owner signs off on the safety-aware exception. This places acceptance of the iot profiling and containment change with its accountable owner rather than an unrelated service team. The reported condition is an industrial gateway stops reporting telemetry because a new threat policy blocks a legitimate proprietary protocol it misclassifies.

Incorrect Answers

A:

The management compatibility owner approves supported release pairing. That function does not own this iot profiling and containment decision; accountable approval belongs to The plant control security owner signs off on the safety-aware exception.

C:

The operations observability owner approves VPN probe target maintenance. That function does not own this iot profiling and containment decision; accountable approval belongs to The plant control security owner signs off on the safety-aware exception.

D:

The VPN address-plan owner approves nonoverlapping selectors. That function does not own this iot profiling and containment decision; accountable approval belongs to The plant control security owner signs off on the safety-aware exception.

Security, Specialist (JNCIS-SEC) (JN0-336) Practice Tests

UP

SPECIAL OFFER: GET 10% OFF

This is ONE TIME OFFER

ExamSnap Discount Offer
Enter Your Email Address to Receive Your 10% Off Discount Code

A confirmation link will be sent to this email address to verify your login. *We value your privacy. We will not rent or sell your email address.

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.