Network Appliance NS0-094 Practice Test 29

Question 280

A lab host Host-57 uses two independent storage paths to LUN-LAB-18, one through Fabric-A-7 and one through Fabric-B-7. Observations: Observation-8-A: A=unavailable, B=available; Observation-8-B: A=unavailable, B=unavailable; Observation-8-C: A=available, B=available; Observation-8-D: A=available, B=unavailable. The worksheet classifies two paths as redundant, one as degraded, none as unavailable. Which THREE statements correctly follow from the scenario?

  1. Observation-8-B has 1 usable path(s)
  2. Observation-8-A has 1 usable path(s)
  3. Observation-8-C has 2 usable path(s)
  4. Observation-8-B has 0 usable path(s)
  5. Observation-8-C has 0 usable path(s)
  6. Observation-8-A has 2 usable path(s)

Explanation

Correct Answers

B:

Observation-8-A shows A=False and B=True; the sum of those availability indicators is 1.

C:

Observation-8-C shows A=True and B=True; the sum of those availability indicators is 2.

D:

Observation-8-B shows A=False and B=False; the sum of those availability indicators is 0.

Incorrect Answers

A:

This miscounts the two observed fabric paths for Observation-8-B.

E:

This miscounts the two observed fabric paths for Observation-8-C.

F:

This miscounts the two observed fabric paths for Observation-8-A.

Question 281

A lab support worksheet records a storage-network interface at two samples 30 seconds apart: error counter 120 to 124, frame counter 50000 to 51500. No counter reset or wrap occurred. How many new errors occurred in the sampling interval?

  1. 124 errors
  2. 120 errors
  3. 4 errors
  4. 244 errors

Explanation

Correct Answer

C:

124−120=4.

Incorrect Answers

A:

That is the newer cumulative count, not the delta.

B:

That is the older cumulative count.

D:

Adding cumulative totals double-counts history.

Question 282

A lab support worksheet records a storage-network interface at two samples 30 seconds apart: error counter 120 to 124, frame counter 50000 to 51500. No counter reset or wrap occurred. How many frames were added to the counter?

  1. 51500 frames
  2. 101500 frames
  3. 1500 frames
  4. 50000 frames

Explanation

Correct Answer

C:

51500−50000=1500.

Incorrect Answers

A:

This includes frames before the interval.

B:

This adds accumulated totals.

D:

This is the initial accumulated count.

Question 283

A lab support worksheet records a storage-network interface at two samples 30 seconds apart: error counter 120 to 124, frame counter 50000 to 51500. No counter reset or wrap occurred. What is the average frame rate in the interval (two decimals if needed)?

  1. 0.13 frames/s
  2. 0.83 frames/s
  3. 1716.67 frames/s
  4. 50.0 frames/s

Explanation

Correct Answer

D:

1500/30=50.0 frames/s.

Incorrect Answers

A:

This is the error rate rather than the frame rate.

B:

The interval is already given in seconds.

C:

The numerator must be the interval delta.

Question 284

A lab support worksheet records a storage-network interface at two samples 30 seconds apart: error counter 120 to 124, frame counter 50000 to 51500. No counter reset or wrap occurred. Which conclusion is supported about the interface?

  1. The entire storage system must be replaced
  2. 4 new errors occurred and further diagnosis is warranted
  3. A specific transceiver is conclusively failed
  4. No new errors occurred

Explanation

Correct Answer

B:

A rising error count is current evidence of a link issue, but it does not uniquely identify the cable or module.

Incorrect Answers

A:

The observations concern one interface and do not justify a broad replacement.

C:

The counters do not identify a single root cause.

D:

The second error total exceeds the first.

Question 285

A lab support worksheet records a storage-network interface at two samples 30 seconds apart: error counter 120 to 124, frame counter 50000 to 51500. No counter reset or wrap occurred. Which TWO statements correctly follow from the scenario?

  1. Count 124 errors as new events
  2. Ignore future counter resets under all circumstances
  3. Use 4 as new errors
  4. Infer a particular failed FRU from counters alone
  5. Use 1500 as interval frame count

Explanation

Correct Answers

C:

Subtract the initial counter from the final counter.

E:

The frame total increased by this amount.

Incorrect Answers

A:

That is a lifetime count at the second sample.

B:

The no-reset condition was only specified for this interval.

D:

Further supporting diagnostics are required.

Question 286

A lab support worksheet records a storage-network interface at two samples 35 seconds apart: error counter 131 to 137, frame counter 52000 to 53950. No counter reset or wrap occurred. How many new errors occurred in the sampling interval?

  1. 137 errors
  2. 268 errors
  3. 6 errors
  4. 131 errors

Explanation

Correct Answer

C:

137−131=6.

Incorrect Answers

A:

That is the newer cumulative count, not the delta.

B:

Adding cumulative totals double-counts history.

D:

That is the older cumulative count.

Question 287

A lab support worksheet records a storage-network interface at two samples 35 seconds apart: error counter 131 to 137, frame counter 52000 to 53950. No counter reset or wrap occurred. How many frames were added to the counter?

  1. 53950 frames
  2. 1950 frames
  3. 52000 frames
  4. 105950 frames

Explanation

Correct Answer

B:

53950−52000=1950.

Incorrect Answers

A:

This includes frames before the interval.

C:

This is the initial accumulated count.

D:

This adds accumulated totals.

Question 288

A lab support worksheet records a storage-network interface at two samples 35 seconds apart: error counter 131 to 137, frame counter 52000 to 53950. No counter reset or wrap occurred. What is the average frame rate in the interval (two decimals if needed)?

  1. 1541.43 frames/s
  2. 0.93 frames/s
  3. 0.17 frames/s
  4. 55.71 frames/s

Explanation

Correct Answer

D:

1950/35=55.71 frames/s.

Incorrect Answers

A:

The numerator must be the interval delta.

B:

The interval is already given in seconds.

C:

This is the error rate rather than the frame rate.

Question 289

A lab support worksheet records a storage-network interface at two samples 35 seconds apart: error counter 131 to 137, frame counter 52000 to 53950. No counter reset or wrap occurred. Which conclusion is supported about the interface?

  1. The entire storage system must be replaced
  2. A specific transceiver is conclusively failed
  3. No new errors occurred
  4. 6 new errors occurred and further diagnosis is warranted

Explanation

Correct Answer

D:

A rising error count is current evidence of a link issue, but it does not uniquely identify the cable or module.

Incorrect Answers

A:

The observations concern one interface and do not justify a broad replacement.

B:

The counters do not identify a single root cause.

C:

The second error total exceeds the first.

Question 290

A lab support worksheet records a storage-network interface at two samples 35 seconds apart: error counter 131 to 137, frame counter 52000 to 53950. No counter reset or wrap occurred. Which THREE statements correctly follow from the scenario?

  1. Use 6 as new errors
  2. Use 35 seconds for average rate
  3. Infer a particular failed FRU from counters alone
  4. Use 1950 as interval frame count
  5. Count 137 errors as new events
  6. Ignore future counter resets under all circumstances

Explanation

Correct Answers

A:

Subtract the initial counter from the final counter.

B:

The worksheet explicitly provides the interval.

D:

The frame total increased by this amount.

Incorrect Answers

C:

Further supporting diagnostics are required.

E:

That is a lifetime count at the second sample.

F:

The no-reset condition was only specified for this interval.

NetApp Hardware Support Engineer Professional (NS0-094) Practice Tests

UP

SPECIAL OFFER: GET 10% OFF

This is ONE TIME OFFER

ExamSnap Discount Offer
Enter Your Email Address to Receive Your 10% Off Discount Code

A confirmation link will be sent to this email address to verify your login. *We value your privacy. We will not rent or sell your email address.

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.