Question 430
A system reports loss of one power supply but both cords were recently moved to the same distribution unit. Which THREE statements correctly follow from the scenario?
- Evidence identifying the affected supply or power path
- Treat a shared distribution unit as independent feeds
- Supply hardware state versus upstream feed availability
- Assume all power supplies failed
- Move cords without checking the approved maintenance plan
- The intended independent feed mapping
Explanation
Correct Answers
A:A correct diagnosis avoids unnecessary FRU replacement.
C:A feed problem can mimic an equipment power problem.
F:Both cords on one source may defeat redundancy.
Incorrect Answers
B:The supplies would share the upstream failure domain.
D:The observations do not establish this.
E:The action might interrupt the surviving feed.
Question 431
An engineer receives a replacement drive whose documented capacity is adequate but whose supported platform qualification is unknown. What is the decisive compatibility criterion?
- Relabel the drive with a supported part number
- The exact supported drive and platform combination
- Use an unrelated desktop drive guide
- Ignore supported firmware requirements
Explanation
Correct Answer
B:Capacity alone is insufficient to qualify a storage FRU.
Incorrect Answers
A:Changing a label does not change qualification.
C:Its replacement sequence is not applicable.
D:The supported combination may include firmware conditions.
Question 432
An engineer receives a replacement drive whose documented capacity is adequate but whose supported platform qualification is unknown. What should be reconciled?
- Use an unrelated desktop drive guide
- Use capacity as the sole qualification
- Ignore supported firmware requirements
- Drive model, part identifier and platform record
Explanation
Correct Answer
D:Exact identifiers distinguish superficially similar devices.
Incorrect Answers
A:Its replacement sequence is not applicable.
B:Capacity does not establish interface and firmware compatibility.
C:The supported combination may include firmware conditions.
Question 433
An engineer receives a replacement drive whose documented capacity is adequate but whose supported platform qualification is unknown. What should happen to the replacement before authorization?
- Relabel the drive with a supported part number
- Keep it out of the production system
- Use capacity as the sole qualification
- Ignore supported firmware requirements
Explanation
Correct Answer
B:An unverified drive may not be supported.
Incorrect Answers
A:Changing a label does not change qualification.
C:Capacity does not establish interface and firmware compatibility.
D:The supported combination may include firmware conditions.
Question 434
An engineer receives a replacement drive whose documented capacity is adequate but whose supported platform qualification is unknown. Where should the technician obtain replacement prerequisites?
- The platform-specific drive replacement documentation
- Relabel the drive with a supported part number
- Use capacity as the sole qualification
- Use an unrelated desktop drive guide
Explanation
Correct Answer
A:Drive types and replacement conditions vary.
Incorrect Answers
B:Changing a label does not change qualification.
C:Capacity does not establish interface and firmware compatibility.
D:Its replacement sequence is not applicable.
Question 435
An engineer receives a replacement drive whose documented capacity is adequate but whose supported platform qualification is unknown. Which TWO statements correctly follow from the scenario?
- The exact supported drive and platform combination
- Use capacity as the sole qualification
- Relabel the drive with a supported part number
- Use an unrelated desktop drive guide
- Drive model, part identifier and platform record
Explanation
Correct Answers
A:Capacity alone is insufficient to qualify a storage FRU.
E:Exact identifiers distinguish superficially similar devices.
Incorrect Answers
B:Capacity does not establish interface and firmware compatibility.
C:Changing a label does not change qualification.
D:Its replacement sequence is not applicable.
Question 436
A controller's event log lists a memory-related fault with a slot identifier; inventory shows several identical modules. What should be identified?
- The exact indicated module location using the model's slot mapping
- Ignore slot mapping
- Remove modules from a running controller indiscriminately
- Assume every DIMM is faulty
Explanation
Correct Answer
A:Identical appearance cannot identify the affected slot.
Incorrect Answers
B:A location error could replace the wrong FRU.
C:The service procedure may require a controlled state.
D:One slot report does not establish all modules failed.
Question 437
A controller's event log lists a memory-related fault with a slot identifier; inventory shows several identical modules. What should be captured before servicing?
- Choose a random identical module
- The fault evidence and installed memory inventory
- Ignore slot mapping
- Assume every DIMM is faulty
Explanation
Correct Answer
B:These support diagnosis and post-maintenance comparison.
Incorrect Answers
A:The reported slot is meaningful diagnostic evidence.
C:A location error could replace the wrong FRU.
D:One slot report does not establish all modules failed.
Question 438
A controller's event log lists a memory-related fault with a slot identifier; inventory shows several identical modules. What governs whether a memory module can be replaced?
- Choose a random identical module
- Remove modules from a running controller indiscriminately
- The exact platform procedure and service state prerequisites
- Ignore slot mapping
Explanation
Correct Answer
C:Memory is not universally hot-replaceable.
Incorrect Answers
A:The reported slot is meaningful diagnostic evidence.
B:The service procedure may require a controlled state.
D:A location error could replace the wrong FRU.
Question 439
A controller's event log lists a memory-related fault with a slot identifier; inventory shows several identical modules. What should be verified after authorized work?
- Expected memory inventory and absence of the relevant recurring fault
- Remove modules from a running controller indiscriminately
- Choose a random identical module
- Assume every DIMM is faulty
Explanation
Correct Answer
A:Both capacity and fault state contribute to validation.
Incorrect Answers
B:The service procedure may require a controlled state.
C:The reported slot is meaningful diagnostic evidence.
D:One slot report does not establish all modules failed.
Question 440
A controller's event log lists a memory-related fault with a slot identifier; inventory shows several identical modules. Which THREE statements correctly follow from the scenario?
- The exact platform procedure and service state prerequisites
- The fault evidence and installed memory inventory
- Assume every DIMM is faulty
- The exact indicated module location using the model's slot mapping
- Remove modules from a running controller indiscriminately
- Choose a random identical module
Explanation
Correct Answers
A:Memory is not universally hot-replaceable.
B:These support diagnosis and post-maintenance comparison.
D:Identical appearance cannot identify the affected slot.
Incorrect Answers
C:One slot report does not establish all modules failed.
E:The service procedure may require a controlled state.
F:The reported slot is meaningful diagnostic evidence.