100% Latest & Updated Network Appliance NS0-094 Practice Test Questions, Exam Dumps & Verified Answers!
30 Days Free Updates, Instant Download!
Question 500
A shelf reports several inaccessible drives at the same time, and all affected positions share one recorded connectivity branch. Which THREE statements correctly follow from the scenario?
- Isolation of the shared dependency and individual drive evidence
- A shared shelf or connectivity-path problem
- Ignore the common branch
- Declare the unaffected drives failed too
- Replace all drives immediately from the simultaneous report
- Affected drive positions and path events
Explanation
Correct Answers
A:The symptoms may not reflect separate disk failures.
B:Simultaneous faults on a common branch suggest investigating the dependency.
F:The grouping and timing are diagnostically useful.
Incorrect Answers
C:It is a useful diagnostic relationship.
D:The observed pattern does not support that.
E:A common path failure may explain their inaccessibility.
Question 501
An AFF A400 service ticket identifies a failed power supply, but the available printed guide describes AFF A700s. Which guide is applicable?
- The AFF A400 procedure for the installed configuration
- Select a supply solely by wattage
- Ignore the other supply's condition
- Close without checking power status
Explanation
Correct Answer
A:The controller chassis determines relevant hardware instructions.
Incorrect Answers
B:Electrical and platform qualifications also matter.
C:The maintenance may depend on its availability.
D:Redundancy may remain degraded.
Question 502
An AFF A400 service ticket identifies a failed power supply, but the available printed guide describes AFF A700s. Which identity must be matched?
- The actual supply part and supported electrical type
- Ignore the other supply's condition
- Close without checking power status
- Use the A700s guide unchanged
Explanation
Correct Answer
A:Physical similarity is insufficient for power compatibility.
Incorrect Answers
B:The maintenance may depend on its availability.
C:Redundancy may remain degraded.
D:Its chassis may have different service details.
Question 503
An AFF A400 service ticket identifies a failed power supply, but the available printed guide describes AFF A700s. What is checked before removal?
- Use the A700s guide unchanged
- The procedure prerequisites and remaining supply health
- Select a supply solely by wattage
- Close without checking power status
Explanation
Correct Answer
B:The action must not compromise the surviving power path.
Incorrect Answers
A:Its chassis may have different service details.
C:Electrical and platform qualifications also matter.
D:Redundancy may remain degraded.
Question 504
An AFF A400 service ticket identifies a failed power supply, but the available printed guide describes AFF A700s. What is verified afterward?
- Select a supply solely by wattage
- Use the A700s guide unchanged
- Ignore the other supply's condition
- Supply health and restored intended redundancy
Explanation
Correct Answer
D:A working supply is only part of the recovery objective.
Incorrect Answers
A:Electrical and platform qualifications also matter.
B:Its chassis may have different service details.
C:The maintenance may depend on its availability.
Question 505
An AFF A400 service ticket identifies a failed power supply, but the available printed guide describes AFF A700s. Which TWO statements correctly follow from the scenario?
- Ignore the other supply's condition
- The actual supply part and supported electrical type
- Select a supply solely by wattage
- The AFF A400 procedure for the installed configuration
- Use the A700s guide unchanged
Explanation
Correct Answers
B:Physical similarity is insufficient for power compatibility.
D:The controller chassis determines relevant hardware instructions.
Incorrect Answers
A:The maintenance may depend on its availability.
C:Electrical and platform qualifications also matter.
E:Its chassis may have different service details.
Question 506
A replacement chassis is planned for an AFF A200, and the engineer discovers a previously undocumented adapter configuration. What is the initial task?
- Omit the unknown adapter from the inventory
- Use a guide for a different controller family
- Ignore post-change hardware detection
- Confirm the installed adapter configuration against the exact procedure
Explanation
Correct Answer
D:The transfer plan depends on actual inventory.
Incorrect Answers
A:This conceals an unresolved configuration.
B:The guide may not match the chassis.
C:Undetected devices could affect service.
Question 507
A replacement chassis is planned for an AFF A200, and the engineer discovers a previously undocumented adapter configuration. What should the engineer preserve?
- Ignore post-change hardware detection
- Assume all adapters can be moved arbitrarily
- Use a guide for a different controller family
- The adapter identities and their original positions
Explanation
Correct Answer
D:These provide a reference for restoration.
Incorrect Answers
A:Undetected devices could affect service.
B:Position and compatibility requirements may apply.
C:The guide may not match the chassis.
Question 508
A replacement chassis is planned for an AFF A200, and the engineer discovers a previously undocumented adapter configuration. What should be escalated?
- Omit the unknown adapter from the inventory
- Assume all adapters can be moved arbitrarily
- Any unsupported or unrecognized configuration
- Ignore post-change hardware detection
Explanation
Correct Answer
C:The applicable service sequence must be established.
Incorrect Answers
A:This conceals an unresolved configuration.
B:Position and compatibility requirements may apply.
D:Undetected devices could affect service.
Question 509
A replacement chassis is planned for an AFF A200, and the engineer discovers a previously undocumented adapter configuration. What validates completion?
- Omit the unknown adapter from the inventory
- Restored intended inventory and functional service
- Use a guide for a different controller family
- Assume all adapters can be moved arbitrarily
Explanation
Correct Answer
B:A mechanically complete chassis swap is insufficient.
Incorrect Answers
A:This conceals an unresolved configuration.
C:The guide may not match the chassis.
D:Position and compatibility requirements may apply.
Question 510
A replacement chassis is planned for an AFF A200, and the engineer discovers a previously undocumented adapter configuration. Which THREE statements correctly follow from the scenario?
- Any unsupported or unrecognized configuration
- Use a guide for a different controller family
- Confirm the installed adapter configuration against the exact procedure
- Assume all adapters can be moved arbitrarily
- The adapter identities and their original positions
- Omit the unknown adapter from the inventory
Explanation
Correct Answers
A:The applicable service sequence must be established.
C:The transfer plan depends on actual inventory.
E:These provide a reference for restoration.
Incorrect Answers
B:The guide may not match the chassis.
D:Position and compatibility requirements may apply.
F:This conceals an unresolved configuration.
NetApp Hardware Support Engineer Professional (NS0-094) Practice Tests