Network Appliance NS0-094 Practice Test 5

Question 40

A simulated shelf-path inventory for Node-18 expects two independent usable paths per shelf. Current observations: Shelf-41: path A=up, path B=down; Shelf-42: path A=down, path B=down; Shelf-43: path A=up, path B=up. This is a diagnostic worksheet, not a model-specific cabling procedure. Which THREE statements correctly follow from the scenario?

  1. Treat the status of Shelf-43 as proof all shelves are healthy
  2. Declare Shelf-42 a failed shelf solely from path counts
  3. Remove a surviving path from Shelf-41 without a maintenance assessment
  4. Shelf-43 has full observed path count
  5. Shelf-41 has lost path redundancy
  6. Shelf-42 has no observed usable path

Explanation

Correct Answers

D:

Both paths are up in the worksheet.

E:

A single usable path remains.

F:

Both paths are down; investigate connectivity and affected service.

Incorrect Answers

A:

Each shelf has its own observed path state.

B:

The underlying cause still requires diagnosis.

C:

The remaining usable path is the only currently observed connectivity.

Question 41

A planning worksheet for Cabinet-11 has independently fed redundant power paths A and B. Each path, if it is the sole surviving path, can supply up to 1500 W and 1400 W respectively. The protected modeled load is 1000 W. Ignore transient inrush and apply this simplified capacity model only. What is the margin on surviving feed A if B fails?

  1. 500 W
  2. 1500 W
  3. 400 W
  4. 2500 W

Explanation

Correct Answer

A:

1500 W capacity minus 1000 W modeled load leaves 500 W.

Incorrect Answers

B:

The protected load still consumes capacity.

C:

That is the margin for feed B.

D:

Load must be subtracted, not added.

Question 42

A planning worksheet for Cabinet-11 has independently fed redundant power paths A and B. Each path, if it is the sole surviving path, can supply up to 1500 W and 1400 W respectively. The protected modeled load is 1000 W. Ignore transient inrush and apply this simplified capacity model only. What is the margin on surviving feed B if A fails?

  1. 400 W
  2. 500 W
  3. 1400 W
  4. 2400 W

Explanation

Correct Answer

A:

1400−1000=400 W.

Incorrect Answers

B:

That is the margin on A.

C:

This omits the protected load.

D:

The load reduces available margin.

Question 43

A planning worksheet for Cabinet-11 has independently fed redundant power paths A and B. Each path, if it is the sole surviving path, can supply up to 1500 W and 1400 W respectively. The protected modeled load is 1000 W. Ignore transient inrush and apply this simplified capacity model only. What is the largest modeled load that either surviving feed alone could support?

  1. 1000 W
  2. 1500 W
  3. 2900 W
  4. 1400 W

Explanation

Correct Answer

D:

For either single-feed failure, the smaller capacity (1400 W) determines the limit.

Incorrect Answers

A:

The current load is not the maximum modeled capacity.

B:

This only fits the larger feed.

C:

Combined capacity is not available when only one feed survives.

Question 44

A planning worksheet for Cabinet-11 has independently fed redundant power paths A and B. Each path, if it is the sole surviving path, can supply up to 1500 W and 1400 W respectively. The protected modeled load is 1000 W. Ignore transient inrush and apply this simplified capacity model only. Does the current modeled load fit either single-feed survival condition?

  1. Assume physical redundancy guarantees no service interruption
  2. Yes, using the smaller feed capacity of 1400 W
  3. Add the feeds and ignore failure conditions
  4. Treat 1500 W as the limit in both failure cases

Explanation

Correct Answer

B:

1000 W is at or below the smaller capacity; both modeled survival cases fit.

Incorrect Answers

A:

A capacity worksheet does not establish actual failover or model-specific service behavior.

C:

The worksheet asks whether either feed alone can carry the load.

D:

The smaller surviving feed could be the constrained path.

Question 45

A planning worksheet for Cabinet-11 has independently fed redundant power paths A and B. Each path, if it is the sole surviving path, can supply up to 1500 W and 1400 W respectively. The protected modeled load is 1000 W. Ignore transient inrush and apply this simplified capacity model only. Which TWO statements correctly follow from the scenario?

  1. Ignore the 1000 W protected load
  2. Claim actual hardware is validated solely by this arithmetic
  3. Use 2900 W as single-feed capacity
  4. Feed A margin is 500 W
  5. Feed B margin is 400 W

Explanation

Correct Answers

D:

1500−1000=500.

E:

1400−1000=400.

Incorrect Answers

A:

The surviving feed must carry that load.

B:

A real system also requires model-specific support and operational verification.

C:

This is the sum of two feeds, not one.

Question 46

A planning worksheet for Cabinet-12 has independently fed redundant power paths A and B. Each path, if it is the sole surviving path, can supply up to 1700 W and 1575 W respectively. The protected modeled load is 1190 W. Ignore transient inrush and apply this simplified capacity model only. What is the margin on surviving feed A if B fails?

  1. 510 W
  2. 1700 W
  3. 2890 W
  4. 385 W

Explanation

Correct Answer

A:

1700 W capacity minus 1190 W modeled load leaves 510 W.

Incorrect Answers

B:

The protected load still consumes capacity.

C:

Load must be subtracted, not added.

D:

That is the margin for feed B.

Question 47

A planning worksheet for Cabinet-12 has independently fed redundant power paths A and B. Each path, if it is the sole surviving path, can supply up to 1700 W and 1575 W respectively. The protected modeled load is 1190 W. Ignore transient inrush and apply this simplified capacity model only. What is the margin on surviving feed B if A fails?

  1. 385 W
  2. 510 W
  3. 2765 W
  4. 1575 W

Explanation

Correct Answer

A:

1575−1190=385 W.

Incorrect Answers

B:

That is the margin on A.

C:

The load reduces available margin.

D:

This omits the protected load.

Question 48

A planning worksheet for Cabinet-12 has independently fed redundant power paths A and B. Each path, if it is the sole surviving path, can supply up to 1700 W and 1575 W respectively. The protected modeled load is 1190 W. Ignore transient inrush and apply this simplified capacity model only. What is the largest modeled load that either surviving feed alone could support?

  1. 1700 W
  2. 1190 W
  3. 3275 W
  4. 1575 W

Explanation

Correct Answer

D:

For either single-feed failure, the smaller capacity (1575 W) determines the limit.

Incorrect Answers

A:

This only fits the larger feed.

B:

The current load is not the maximum modeled capacity.

C:

Combined capacity is not available when only one feed survives.

Question 49

A planning worksheet for Cabinet-12 has independently fed redundant power paths A and B. Each path, if it is the sole surviving path, can supply up to 1700 W and 1575 W respectively. The protected modeled load is 1190 W. Ignore transient inrush and apply this simplified capacity model only. Does the current modeled load fit either single-feed survival condition?

  1. Assume physical redundancy guarantees no service interruption
  2. Add the feeds and ignore failure conditions
  3. Treat 1700 W as the limit in both failure cases
  4. Yes, using the smaller feed capacity of 1575 W

Explanation

Correct Answer

D:

1190 W is at or below the smaller capacity; both modeled survival cases fit.

Incorrect Answers

A:

A capacity worksheet does not establish actual failover or model-specific service behavior.

B:

The worksheet asks whether either feed alone can carry the load.

C:

The smaller surviving feed could be the constrained path.

Question 50

A planning worksheet for Cabinet-12 has independently fed redundant power paths A and B. Each path, if it is the sole surviving path, can supply up to 1700 W and 1575 W respectively. The protected modeled load is 1190 W. Ignore transient inrush and apply this simplified capacity model only. Which THREE statements correctly follow from the scenario?

  1. Feed A margin is 510 W
  2. Ignore the 1190 W protected load
  3. Feed B margin is 385 W
  4. Either-feed limit is 1575 W
  5. Use 3275 W as single-feed capacity
  6. Claim actual hardware is validated solely by this arithmetic

Explanation

Correct Answers

A:

1700−1190=510.

C:

1575−1190=385.

D:

The smaller of the independently surviving capacities governs the condition.

Incorrect Answers

B:

The surviving feed must carry that load.

E:

This is the sum of two feeds, not one.

F:

A real system also requires model-specific support and operational verification.

NetApp Hardware Support Engineer Professional (NS0-094) Practice Tests

UP

SPECIAL OFFER: GET 10% OFF

This is ONE TIME OFFER

ExamSnap Discount Offer
Enter Your Email Address to Receive Your 10% Off Discount Code

A confirmation link will be sent to this email address to verify your login. *We value your privacy. We will not rent or sell your email address.

Download Free Demo of VCE Exam Simulator

Experience Avanset VCE Exam Simulator for yourself.

Simply submit your e-mail address below to get started with our interactive software demo of your free trial.

Free Demo Limits: In the demo version you will be able to access only first 5 questions from exam.